Temperature sensor insulation
requirement
Temperature sensor
type
Option module
Pt100,
Pt1000
KTY
PTC
Insulation/Isolation
Type
Reinforced insulation
x
x
-
Galvanic isolation between sensor
connector and other connectors (in-
cluding drive control unit connector)
FIO-11
Reinforced insulation
-
x
x
Galvanic isolation between sensor
connector and other connectors (in-
cluding drive control unit connector)
FEN-xx
Basic insulation. Connectors of op-
tion module other than sensor con-
nector must be left unconnected.
x
x
x
Basic insulation between sensor
connector and drive control unit
connector. No insulation between
sensor connector and other I/O
connectors.
FAIO-01
No special requirement
-
-
x
Reinforced insulation between
sensor connector and other connect-
ors (including drive control unit con-
nector).
FPTC-
xx
1)
1) Suitable for use in safety functions (SIL2 / PL c rated).
■
Connection of motor temperature sensor to the drive via a relay
PTC alternative A: This table shows the insulation requirement for a customer’s external
relay, and the insulation requirement for the sensor to fulfill decisive voltage class A (double
insulation) of IEC 60800-5-1. The table also shows the insulation of the factory-installed
relay (plus code option for a cabinet-installed drive), and the insulation requirement for the
sensor.
Temperature sensor insulation
requirement
PTC relay
Insulation
Type
Basic insulation
Basic insulation 6 kV
External relay
Basic insulation
Basic insulation 6 kV
Drive oL505 and +L513
PTC alternative B: Decisive voltage class B of IEC 60800-5-1 (basic insulation) is provided
with a 6 kV relay. Circuits connected to all motor protection relay inputs and outputs must
be protected against direct contact.
Pt100 alternative A: This table shows the insulation requirement for a customer’s external
relay, and the insulation requirement for the sensor to fulfill decisive voltage class A (double
insulation) of IEC 60800-5-1.The table also shows the insulation of the factory-installed
relay (plus code option for a cabinet-installed drive), and the insulation requirement for the
sensor.
Temperature sensor insulation
requirement
Pt100 relay
Insulation
Type
Basic insulation
Basic insulation 6 kV
External relay
Double or reinforced insulation
Basic insulation < 6 kV
Drive oL506 and +L514
Pt100 alternative B: Decisive voltage class B of IEC 60800-5-1 (basic insulation) can be
achieved when there is basic insulation between the sensor and live parts of the motor.
Electrical planning guidelines 33
Summary of Contents for ACS880 Series
Page 1: ...ABB INDUSTRIAL DRIVES ACS880 liquid cooled multidrive cabinets and modules Electrical planning...
Page 2: ......
Page 4: ......
Page 8: ...8...
Page 40: ...40...
Page 45: ...EU Declaration of Conformity Machinery Directive Multidrive modules Standards and markings 45...
Page 48: ...48...