Cooling data and noise
Noise level
Pressure
loss
Coolant flow rate
Coolant volume
Supply unit type
ACS880-307LC-…
Average
M
cabinet
Modules
M
cabinet
Modules
dB (A)
kPa
l/min
l/min
l
l
U
N
= 690 V
6-pulse
65
120
20
14
3.5
0.6
0490A-7+A018
65
120
20
14
3.5
0.6
0780A-7+A018
65
120
20
14
3.5
0.6
1060A-7+A018
65
120
34
28
4.2
1.2
1470A-7+A018
65
120
34
28
4.2
1.2
2000A-7+A018
67
120
54
42
7.7
1.8
3000A-7+A018
67
120
68
56
8.4
2.4
4000A-7+A018
68
120
88
70
11.9
3.0
5000A-7+A018
68
120
102
84
12.6
3.6
6000A-7+A018
12-pulse
67
120
34
28
4.2
1.2
0920A-7+A004+A018
67
120
34
28
4.2
1.2
1470A-7+A004+A018
67
120
34
28
4.2
1.2
2000A-7+A004+A018
68
120
68
56
8.4
2.4
2940A-7+A004+A018
68
120
68
56
8.4
2.4
4000A-7+A004+A018
68
120
102
84
12.6
3.6
6000A-7+A004+A018
Terminal and cable entry data for the input power cable
These drawings (from front, side and above) show the terminal and cable entry dimensions
for incoming cubicles. The dimensions are given in millimeters. Tightening torque for the
cable lug connection depends on the bolt size and type. See section
Technical data 95
Summary of Contents for ACS880-307LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 307LC diode supply units Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 34: ...34 ...
Page 41: ...10 9 7 6 8 Electrical installation 41 11 ...
Page 73: ...11 12 12 6 10 Maintenance 73 ...
Page 78: ...78 ...
Page 88: ...88 ...
Page 96: ... 400 mm wide input cubicle 96 Technical data ...
Page 97: ... 600 mm wide incoming cubicle or input cubicle Technical data 97 ...