134 Parameters
DI1
Digital input DI1 (as indicated by
1073742337
DI2
Digital input DI2 (as indicated by
1073807873
DI3
Digital input DI3 (as indicated by
1073873409
DI4
Digital input DI4 (as indicated by
1073938945
DI5
Digital input DI5 (as indicated by
1074004481
DI6
Digital input DI6 (as indicated by
1074070017
DIO4
Digital input/output DIO4 (as indicated by
,
bit 3).
1073938947
DIO5
Digital input/output DIO5 (as indicated by
,
bit 4).
1074004483
DIO6
Digital input/output DIO6 (as indicated by
,
bit 5).
1074070019
Const
Bit pointer setting (see
on page
-
Pointer
12.03
Ext1 ctrl mode
Selects the operating mode for external control location
EXT1.
Speed
Speed control. The speed controller output (torque reference)
is
1
Torque
Torque control. Torque reference is
2
Min
Combination of selections
and
: Torque selector
compares the torque reference and the speed controller
output and the smaller of the two is used.
3
Max
Combination of selections
and
: Torque selector
compares the torque reference and the speed controller
output and the greater of the two is used.
4
Add
Combination of selections
and
: Torque selector
adds the speed controller output to the torque reference.
5
12.05
Ext2 ctrl mode
Selects the operating mode for external control location
EXT2.
Speed
Speed control. The speed controller output (torque reference)
is
1
Torque
Torque control. Torque reference is
2
Min
Combination of selections
and
: Torque selector
compares the torque reference and the speed controller
output and the smaller of the two is used.
3
Max
Combination of selections
and
: Torque selector
compares the torque reference and the speed controller
output and the greater of the two is used.
4
Add
Combination of selections
and
: Torque selector
adds the speed controller output to the torque reference.
5
12.07
Local ctrl mode
Selects the operating mode for local control.
Speed
Speed control. Torque reference is
.
1
Torque
Torque control. Torque reference is
2
No.
Name/Value
Description
FbEq
Summary of Contents for ACS850 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program ...
Page 4: ......
Page 56: ...56 Control locations and operating modes ...
Page 262: ...262 Parameters ...
Page 310: ...310 Fault tracing ...
Page 348: ...348 Control through a fieldbus adapter ...
Page 358: ...358 Drive to drive link ...