232 Fault tracing
2052
COOLALARM
(0x4290)
Drive module temperature is
excessive.
Check ambient temperature. If it exceeds
40 °C (104 °F), ensure that load current
does not exceed derated load capacity of
drive. See appropriate
Hardware Manual.
Check drive module cooling air flow and
fan operation.
Check inside of cabinet and heatsink of
drive module for dust pick-up. Clean
whenever necessary.
2053
MENU CHG
PASSWORD REQ
(0x6F81)
Loading a parameter listing
requires a password.
Enter password at parameter
2054
MENU CHANGED
(0x6F82)
A different parameter listing is
being loaded.
Informative alarm.
2055
DEVICE CLEAN
(0x5080)
Maintenance alarm.
See parameter group
.
2056
COOLING FAN
(0x5081)
Maintenance alarm.
See parameter group
.
2057
ADD COOLING
(0x5082)
Maintenance alarm.
See parameter group
.
2058
CABINET FAN
(0x5083)
Maintenance alarm.
See parameter group
.
2059
DC CAPACITOR
(0x5084)
Maintenance alarm.
See parameter group
.
2060
MOTOR BEARING
(0x738C)
Maintenance alarm.
See parameter group
.
2061
MAIN CONTACTOR
(0x548D)
Maintenance alarm.
See parameter group
.
2062
RELAY OUTPUT SW
(0x548E)
Maintenance alarm.
See parameter group
.
2063
MOTOR START
COUNT
(0x6180)
Maintenance alarm.
See parameter group
.
2064
POWER UP COUNT
(0x6181)
Maintenance alarm.
See parameter group
.
2065
DC CHARGE COUNT
(0x6182)
Maintenance alarm.
See parameter group
.
2066
ONTIME1 ALARM
(0x5280)
Maintenance alarm.
See parameter group
.
2067
ONTIME2 ALARM
(0x5281)
Maintenance alarm.
See parameter group
.
2068
EDGE1 ALARM
(0x5282)
Maintenance alarm.
See parameter group
.
2069
EDGE2 ALARM
(0x5283)
Maintenance alarm.
See parameter group
.
2070
VALUE1 ALARM
(0x5284)
Maintenance alarm.
See parameter group
.
2071
VALUE2 ALARM
(0x5285)
Maintenance alarm.
See parameter group
.
Code
Alarm
(fieldbus code)
Cause
What to do