background image

Hardware description

9

Hardware description

What this chapter contains

This chapter shows an overview of the APBU-44C(E) unit and describes the 
connectors, settings and LEDs.

APBU-44C(E) overview

The APBU-44C(E) PPCS Branching and Datalogger Unit is used to implement the 
parallel connection of multiple ACS800 series inverter or supply modules. The 
APBU-44C(E) also contains a datalogger for collecting and storing real-time data 
from the module power stages to help fault tracing and analysis.

The APBU-44C(E) is a DIN rail-mountable unit and requires an external 24 V DC 
power source.

The APBU-44C(E) is connected in the PPCS fibre optic link between the RDCU 
drive control unit and the modules. The APBU-44C has connections for four inverter 
or supply modules, while the APBU-44CE has connections for twelve.

Summary of Contents for ACS800 Multidrive

Page 1: ...ACS800 Multidrive Hardware Manual APBU 44C E PPCS Branching and Datalogger Unit ...

Page 2: ......

Page 3: ...APBU 44C E PPCS Branching and Datalogger Unit Hardware Manual 3AFE68464251 REV A EN EFFECTIVE 01 02 2005 2005 ABB Oy All Rights Reserved ...

Page 4: ......

Page 5: ...are description 9 What this chapter contains 9 APBU 44C E overview 9 Installation 11 What this chapter contains 11 Planning the installation of the APBU unit 11 Mounting and removing the APBU 11 Connections 12 Fibre optic connections V1 14 also V21 36 with APBU 44CE 12 Power connection X1 13 Settings 14 DDCS address setting S1 S2 14 Mode switch S3 15 Memory backup battery actuator 6 15 Technical d...

Page 6: ...Table of contents 6 ...

Page 7: ...tended audience The manual describes the APBU 44C E unit and its usage It also gives instructions for installing the unit in a user defined cabinet The manual is intended for cabinet designers and installation personnel of ACS800 Multidrive modules and commissioning and maintenance personnel of ACS800 Multidrive modules and ACS800 Multidrive The reader is expected to know the standard electrical w...

Page 8: ...s Address any inquiries about the product to the local ABB representative quoting the type code and the serial number of the unit If the local ABB representative cannot be contacted address inquiries to the manufacturing facility ...

Page 9: ... ACS800 series inverter or supply modules The APBU 44C E also contains a datalogger for collecting and storing real time data from the module power stages to help fault tracing and analysis The APBU 44C E is a DIN rail mountable unit and requires an external 24 V DC power source The APBU 44C E is connected in the PPCS fibre optic link between the RDCU drive control unit and the modules The APBU 44...

Page 10: ...c links to inverter modules 1 4 V9 V10 CNTL 1 Fibre optic link to RDCU drive control unit V11 V12 CNTL 2 OR DDCS PC Fibre optic link DDCS to PC for controlling the operation of the datalogger and for transferring collected data to PC V13 V14 TRIGGER Connection for external testing equipment datalogger trigger pulse input output V21 V36 CH5 CH12 Fibre optic links to inverter modules 5 12 Only avail...

Page 11: ... temperature meets the requirement given in chapter Technical data WARNING Avoid installing the APBU in the immediate vicinity of sources of electromagnetic disturbance such as relays contactors brake choppers and motor cabling The minimum recommended distance from such components is 200 mm Mounting and removing the APBU The unit can be installed onto a 7 5 35 mm EN50022 mounting rail 1 2 Remove t...

Page 12: ...optic cables make sure that receivers RXD are connected to transmitters TXD Do not remove the protective rubber plugs from unisued optical connectors AINT V1 V2 Inverter or IGBT supply module 12 AINT V1 V2 Inverter or IGBT supply module 4 AINT V1 V2 Inverter or IGBT supply module 3 AINT V1 V2 Inverter or IGBT supply module 2 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 AINT V1 V2 Inverter or...

Page 13: ...4 VDC supply Two power supplies can be used for redundancy R X D B A T T X D P W R 2 4 V D C I N X 1 1 2 3 4 2 4 V A G N D 2 4 V B G N D 24 VDC Power supply R X D B A T T X D P W R 2 4 V D C I N X 1 1 2 3 4 2 4 V A G N D 2 4 V B G N D 24 VDC Power supply A 24 VDC Power supply B ...

Page 14: ... when it is connected to a DDCS link typically a PC The DDCS address is the combined value of S1 and S2 S1 S2 DDCS address Notes 0 0 00h 0 1 01h Default 0 F 0Fh 1 0 10h F F FFh 9 A B 8 C D E F 0 1 2 3 4 5 6 9 A B 8 C D E F 0 1 2 3 4 5 6 1 2 3 4 5 6 D I P O N B A R C O D E L A B E L L O G I C V E R S I O N S1 S2 ...

Page 15: ...n the APBU 44C E is powered and the battery is switched on S3 actuator 6 is set to ON Actuator Name Default setting Description 1 OPT PWR V11 OFF Power setting for optical transmitter V11 OFF Short max 20 m for POF max 50 m for HCS ON Long max 30 m for POF max 200 m for HCS 2 TEST 1 OFF Factory test use only Leave in default position 3 TEST 2 OFF 4 MODE 1 OFF Reserved Leave in default position 5 M...

Page 16: ...Installation 16 ...

Page 17: ...rnal protection Microfuse 1 A slow Operating voltage 24 VDC 10 Current consumption 200 mA typical 250 mA max APBU 44C 350 mA typical 400 mA max APBU 44CE 4 pin detachable screw terminal block Maximum wire size 2 5 mm2 DDCS address switches S1 S2 Two 16 position rotary switches representing the numbers 0 F hex S1 4 most significant bits of the address S2 4 least significant bits of the address Mode...

Page 18: ...Technical data 18 ...

Page 19: ... R X D B A T T X D P W R 2 4 V D C I N D D C S N O D E A D D R T R I G G E R C H 1 C H 2 C H 5 C H 6 C H 3 C H 4 C H 7 C H 8 C N T L 1 C N T L 2 O R D D C S P C S 3 1 6 V 1 V 2 V 3 V 4 V 5 V 6 V 7 V 8 V 9 V 1 0 V 1 1 V 1 2 V 2 1 V 2 2 V 2 3 V 2 4 V 2 5 V 2 6 V 2 7 V 2 8 S 1 S 2 O N O F F X 1 V 1 3 V 1 4 C H 9 C H 1 0 V 2 9 V 3 0 V 3 1 V 3 2 C H 1 1 C H 1 2 V 3 3 V 3 4 V 3 5 V 3 6 1 2 3 4 2 4 V A G...

Page 20: ...Dimensions 20 ...

Page 21: ......

Page 22: ...elephone 358 10 22 11 Fax 358 10 22 22681 Internet http www abb com ABB Inc Automation Technologies Drives Motors 16250 West Glendale Drive New Berlin WI 53151 USA Telephone 262 785 3200 800 HELP 365 Fax 262 780 5135 3AFE68464251 REV A EN EFFECTIVE 01 02 2005 ...

Reviews: