Mechanical installation – Frames R6 to R9 49
Flange kit contents
Mounting template
The flange mounting kit package includes a template in actual size for drilling the
attaching holes and cutting the hole in the mounting plate.
An example template is shown below.
* The delivery does not include the Rivet or Kalei
nuts for the M6 screws.
1
Quick guide
2
Mounting template
3
Top bracket
4
Bottom bracket
5
Side brackets
6
Top cardboard cover
7
Option kit package label
8
Screw package:
• M6 nut (11 pcs)
• M6×10 T30 (12 pcs) *
• M6×25 T25 (R6…R8: 16 pcs,
R9: 18 pcs)
9
Hood (required for UL type 12)
10
Cardboard tray
8
2
1
7
5
3
4
6
9
10
Summary of Contents for ACS580-01 Series
Page 1: ... ABB DRIVES ACS580 01 ACH580 01 and ACQ580 01 C135 drives with flange mounting kit Supplement ...
Page 2: ... ...
Page 4: ......
Page 16: ...16 Mechanical installation General ...
Page 46: ...46 Mechanical installation Frames R4 and R5 ...
Page 56: ...56 Dimension drawings Frame R1 3AXD50000131310 ...
Page 57: ...Dimension drawings 57 3AXD50000131242 Hood is needed for UL Type 12 installation only ...
Page 58: ...58 Dimension drawings Attaching points and hole dimensions 3AXD50000035517 ...
Page 59: ...Dimension drawings 59 Frame R2 3AXD50000131327 ...
Page 60: ...60 Dimension drawings 3AXD50000131242 Hood is needed for UL Type 12 installation only ...
Page 61: ...Dimension drawings 61 Attaching points and hole dimensions 3AXD50000035597 ...
Page 62: ...62 Dimension drawings Frame R3 3AXD50000131143 ...
Page 63: ...Dimension drawings 63 3AXD50000130870 Hood is needed for UL Type 12 installation only ...
Page 64: ...64 Dimension drawings Attaching points and hole dimensions 3AXD50000036519 ...
Page 65: ...Dimension drawings 65 Frame R4 3AXD50000038122 ...
Page 66: ...66 Dimension drawings 3AXD50000038179 Hood is needed for UL Type 12 installation only ...
Page 67: ...Dimension drawings 67 Attaching points and hole dimensions 3AXD50000036765 ...
Page 68: ...68 Dimension drawings Frame R5 3AXD50000038123 ...
Page 69: ...Dimension drawings 69 3AXD50000038180 Hood is needed for UL Type 12 installation only ...
Page 70: ...70 Dimension drawings Attaching points and hole dimensions 3AXD50000430598 ...
Page 71: ...Dimension drawings 71 Frame R6 3AXD50000021919 ...
Page 72: ...72 Dimension drawings Hood is needed for UL Type 12 installation only 3AXD50000021919 ...
Page 73: ...Dimension drawings 73 Attaching points and hole dimensions 3AXD50000019323 ...
Page 74: ...74 Dimension drawings Frame R7 3AXD50000021920 ...
Page 75: ...Dimension drawings 75 Hood is needed for UL Type 12 installation only 3AXD50000021920 ...
Page 76: ...76 Dimension drawings Attaching points and hole dimensions 3AXD50000019324 ...
Page 77: ...Dimension drawings 77 Frame R8 3AXD50000021921 ...
Page 78: ...78 Dimension drawings Hood is needed for UL Type 12 installation only 3AXD50000021921 ...
Page 79: ...Dimension drawings 79 Attaching points and hole dimensions 3AXD50000019325 ...
Page 80: ...80 Dimension drawings Frame R9 3AXD50000021922 ...
Page 81: ...Dimension drawings 81 3AXD50000021922 Hood is needed for UL Type 12 installation only ...
Page 82: ...82 Dimension drawings Attaching points and hole dimensions 3AXD50000019326 ...