Parameters 329
is set to
, this parameter selects the source of actual value
2 transmitted to the fieldbus network through fieldbus adapter
A.
Not selected
No source selected.
-
). -
This parameter enables debug mode. Displays raw
(unmodified) data received from and sent to fieldbus adapter
A in parameters
Disable
Debug mode disabled.
0
Fast
Debug mode enabled. Cyclical data update is as fast as
possible which increases CPU load on the drive.
1
Displays the raw (unmodified) control word sent by the
master (PLC) to fieldbus adapter A if debugging is enabled by
parameter
.
This parameter is read-only.
0.0.0.0
0.0.0.0.0...FF.FF.FF
.FF
Control word sent by master to fieldbus adapter A.
-
Displays raw (unmodified) reference REF1 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
.
This parameter is read-only.
0
-2147483648…
2147483647
Raw REF1 sent by master to fieldbus adapter A.
0
Displays raw (unmodified) reference REF2 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
.
This parameter is read-only.
0
-2147483648…
2147483647
Raw REF2 sent by master to fieldbus adapter A.
-
Displays the raw (unmodified) status word sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
.
This parameter is read-only.
0.0.0.0
0.0.0.0.0...FF.FF.FF
.FF
Status word sent by fieldbus adapter A to master.
-
Displays raw (unmodified) actual value ACT1 sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
.
This parameter is read-only.
0
-2147483648…
2147483647
Raw ACT1 sent by fieldbus adapter A to master.
-
Displays raw (unmodified) actual value ACT2 sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter
.
This parameter is read-only.
0
-2147483648…
2147483647
Raw ACT2 sent by fieldbus adapter A to master.
-
No.
Name/Value
Description
Def/FbEq16
Summary of Contents for ACS560
Page 1: ...ABB GENERAL PURPOSE DRIVES ACS560 standard control program Firmware manual...
Page 4: ...4...
Page 30: ...30 Start up control with I O and ID run...
Page 32: ...32 Using the control panel...
Page 100: ...100 Program features...
Page 153: ...Control macros 153...
Page 160: ...160...
Page 374: ...374 Parameters...
Page 408: ...408 Additional parameter data...
Page 466: ...466 Fieldbus control through the embedded fieldbus interface EFB...
Page 504: ...504 Control chain diagrams...
Page 508: ...508 Parameterization with drive composer...
Page 512: ...512 Parameterization with automation builder drive manager...