Parameters 165
Parameter listing
No.
Name/Value
Description
Def/FbEq16
01
Basic signals for monitoring the drive.
All parameters in this group are read-only unless otherwise
noted.
Note:
Values of these actual signals are filtered with the filter
time defined in group
46 Monitoring/scaling settings
. The
selection lists for parameters in other groups mean the raw
value of the actual signal instead. For example, if a selection
is “Output frequency” it does not point to the value of
parameter
but to the raw value.
Estimated motor speed. A filter time constant for this signal
can be defined by parameter
.
-
-30000.00…
30000.00 rpm
Estimated motor speed.
See par.
Estimated motor speed in rpm. A filter time constant for this
signal can be defined by parameter
-
-30000.00…
30000.00 rpm
Estimated motor speed.
See par.
Motor speed in percent of the synchronous motor speed.
-
-1000.00…
1000.00%
Motor speed.
10 = 1%
Estimated drive output frequency in Hz. A filter time constant
for this signal can be defined by parameter
.
-
-500.00…500.00
Hz
Estimated output frequency.
See par.
Measured (absolute) motor current in A.
-
0.00…30000.00 A
Motor current.
1 = 1 A
Motor current (drive output current) in percent of the nominal
motor current.
-
0.0…1000.0%
Motor current.
1 = 1%
Motor current (drive output current) in percent of the nominal
drive current.
-
0.0…1000.0%
Motor current.
1 = 1%
Motor torque in percent of the nominal motor torque. See also
parameter
A filter time constant for this signal can be defined by
parameter
.
-
-1600.0…1600.0%
Motor torque.
See par.
Measured DC link voltage.
-
0.00…2000.00 V
DC link voltage.
10 = 1 V
Calculated motor voltage in V AC.
-
0…2000 V
Motor voltage.
1 = 1 V
Summary of Contents for ACS560
Page 1: ...ABB GENERAL PURPOSE DRIVES ACS560 standard control program Firmware manual...
Page 4: ...4...
Page 30: ...30 Start up control with I O and ID run...
Page 32: ...32 Using the control panel...
Page 100: ...100 Program features...
Page 153: ...Control macros 153...
Page 160: ...160...
Page 374: ...374 Parameters...
Page 408: ...408 Additional parameter data...
Page 466: ...466 Fieldbus control through the embedded fieldbus interface EFB...
Page 504: ...504 Control chain diagrams...
Page 508: ...508 Parameterization with drive composer...
Page 512: ...512 Parameterization with automation builder drive manager...