98
ACS550 User’s Manual
Complete parameter descriptions
This section describes the actual signals and parameters for ACS550.
Group 99: START-UP DATA
This group defines special start-up data required to:
• set up the drive
• enter motor information.
Code Description
9901
LANGUAGE
Selects the display language. There are two different Assistant Control Panels, each supporting a different language
set. (Panel ACS-CP-L supporting languages 0, 2, 11…15 will be integrated into ACS-CP-A.)
9902
APPLIC MACRO
Selects an application macro. Application macros automatically edit parameters to configure the ACS550 for a
particular application.
31 =
LOAD
FD
SET
– FlashDrop parameter values as defined by the FlashDrop file. Parameter view is selected by
parameter 1611
PARAMETER
VIEW
.
• FlashDrop is an optional device for fast copying of parameters to unpowered drives. FlashDrop allows easy
customization of the parameter list, e.g. selected parameters can be hidden. For more information, see
MFDT-01
FlashDrop User’s Manual
[3AFE68591074 (English)].
-1 =
USER
S
1
SAVE
, -3 =
USER
S
2
SAVE
– With these it is possible to save two different user parameter sets into the
drive permanent memory for later use. Each set contains parameter settings, including
, and the results of the motor identification run.
0 =
USER
S
1
LOAD
, -2 =
USER
S
2
LOAD
– With these the user parameter sets can be taken back in use.
9904
MOTOR CTRL MODE
Selects the motor control mode.
1 =
VECTOR
:
SPEED
– sensorless vector control mode.
• Reference 1 is speed reference in rpm.
• Reference 2 is speed reference in % (100% is absolute maximum speed, equal to the value of parameter 2002
MAXIMUM
SPEED
, or 2001
MINIMUM
SPEED
if the absolute value of the minimum speed is greater than the maximum
speed).
2 =
VECTOR
:
TORQ
.
• Reference 1 is speed reference in rpm.
• Reference 2 is torque reference in % (100% is nominal torque.)
3 =
SCALAR
:
FREQ
– scalar control mode.
• Reference 1 is frequency reference in Hz.
• Reference 2 is frequency reference in % (100% is absolute maximum frequency, equal to the value of parameter
2008
MAXIMUM
FREQ
, or 2007
MINIMUM
FREQ
if the absolute value of the minimum speed is greater than the
maximum speed).
9905
MOTOR NOM VOLT
Defines the nominal motor voltage.
• Must equal the value on the motor rating plate.
• The ACS550 cannot supply the motor with a voltage greater than the input power (mains) voltage.
Assistant Control Panel ACS-CP-A:
Assistant Control Panel ACS-CP-D (Asia):
0 =
ENGLISH
1 =
ENGLISH
(
AM
)
2 =
DEUTSCH
3 =
ITALIANO
4 =
ESPAÑOL
5 =
PORTUGUES
6 =
NEDERLANDS
7 =
FRANÇAIS
8 =
DANSK
9 =
SUOMI
10 =
SVENSKA
11 =
RUSSKI
12 =
POLSKI
13 =
TÜRKÇE
14 =
CZECH
15 =
MAGYAR
0 =
ENGLISH
1 =
CHINESE
2 =
KOREAN
3 =
JAPANESE
1 =
ABB
STANDARD
2 = 3-
WIRE
3 =
ALTERNATE
4 =
MOTOR
POT
5 =
HAND
/
AUTO
6 =
PID
CONTROL
7 =
PFC
CONTROL
8 =
TORQUE
CTRL
31 =
LOAD
FD
SET
0 =
USER
S
1
LOAD
-1 =
USER
S
1
SAVE
-2 =
USER
S
2
LOAD
-3 =
USER
S
2
SAVE
Summary of Contents for ACS550 Series
Page 1: ...ACS550 User s Manual ACS550 01 Drives 0 75 132 kW ACS550 U1 Drives 1 200 hp ...
Page 4: ......
Page 10: ...10 ACS550 User s Manual Table of contents ...
Page 84: ...84 ACS550 User s Manual Application macros ...
Page 188: ...188 ACS550 User s Manual Parameters ...
Page 242: ...242 ACS550 User s Manual Fieldbus adapter ...
Page 276: ...276 ACS550 User s Manual Technical data WARNING Do not use RFI EMC filters on IT systems ...