170
ACS550 User’s Manual
Group 50: ENCODER
This group defines the setup for encoder use:
• Sets the number of encoder pulses per shaft revolution.
• Enables the encoder operation.
• Defines how mechanical angle and revolution data is reset.
See also
User’s Manual for Pulse Encoder Interface Module OTAC-01
[3AUA0000001938 (English)].
Code Description
5001
PULSE NR
Sets the number of pulses provided by an optional encoder for each full motor shaft revolution (ppr).
5002
ENCODER ENABLE
Enables/disables an optional encoder.
0 =
DISABLE
– Drive uses speed feedback derived from the internal motor model (applies for any setting of parameter
9904
MOTOR
CTRL
MODE
).
1 =
ENABLE
– Drive uses feedback from an optional encoder. This function requires the Pulse Encoder Interface
Module (OTAC-01) and an encoder. Operation depends on the setting of parameter 9904
MOTOR
CTRL
MODE
:
• 9904 = 1 (
VECTOR
:
SPEED
): The encoder provides improved speed feedback and improved low speed torque
accuracy.
• 9904 = 2 (
VECTOR
:
TORQ
): The encoder provides improved speed feedback and improved low speed torque
accuracy.
• 9904 = 3 (
SCALAR
:
SPEED
): The encoder provides speed feedback. (This is not closed loop speed regulation.
However, using parameter 2608
SLIP
COMP
RATIO
and an encoder improves steady state speed accuracy.)
5003
ENCODER FAULT
Defines the drive operation if a failure is detected in communication between the encoder and the encoder interface
module, or between the module and the drive.
1 =
FAULT
– The drive generates fault
ENCODER
ERR
, and the motor coasts to a stop.
2 =
ALARM
– The drive generates alarm
ENCODER
ERR
and operates as if parameter 5002
ENCODER
ENABLE
=
0 (
DISABLE
), that is, speed feedback is derived from the internal motor model.
5010
Z PLS ENABLE
Enables/disables the use of an encoder’s Z-pulse to define the motor shaft’s zero position. When enabled, a Z-pulse
input resets parameter 0146
MECH
ANGLE
to zero to define the shaft’s zero position. This function requires an encoder
that provides Z-pulse signals.
0 =
DISABLE
– Z-pulse input is not present or ignored if present.
1 =
ENABLE
– A Z-pulse input resets parameter 0146
MECH
ANGLE
to zero.
5011
POSITION RESET
Resets the encoder’s position feedback. This parameter is self-clearing.
0 =
DISABLE
– Inactive.
1 =
ENABLE
– Resets the encoder position feedback. Parameters reset depends on the state of parameter 5010
Z
PLS
ENABLE
:
• 5010 = 0 (
DISABLE
) – Reset applies to parameters 0147
MECH
REVS
and 0146
MECH
ANGLE
.
• 5010 = 1 (
ENABLE
) – Reset applies only to parameter 0147
MECH
REVS
.
Summary of Contents for ACS550 Series
Page 1: ...ACS550 User s Manual ACS550 01 Drives 0 75 132 kW ACS550 U1 Drives 1 200 hp ...
Page 4: ......
Page 10: ...10 ACS550 User s Manual Table of contents ...
Page 84: ...84 ACS550 User s Manual Application macros ...
Page 188: ...188 ACS550 User s Manual Parameters ...
Page 242: ...242 ACS550 User s Manual Fieldbus adapter ...
Page 276: ...276 ACS550 User s Manual Technical data WARNING Do not use RFI EMC filters on IT systems ...