Actual signals and parameters 245
2609 NOISE
SMOOTHING
Enables the noise smoothing function. Noise smoothing
distributes the acoustic motor noise over a range of
frequencies instead of a single tonal frequency resulting in
lower peak noise intensity. A random component with an
average of 0 Hz is added to the switching frequency set by
parameter
Note:
Parameter has no effect if parameter
is set to 16 kHz.
DISABLE
Disabled
0
ENABLE
Enabled
1
2610 USER
DEFINED U1
Defines the first voltage point of the custom U/f curve at the
frequency defined by parameter
See section
on page
19% of
U
N
0…120% of
U
N
V Voltage
1 = 1 V
2611 USER
DEFINED F1
Defines the first frequency point of the custom U/f curve.
10.0 Hz
0.0…599.0 Hz Frequency
1 = 0.1 Hz
2612 USER
DEFINED U2
Defines the second voltage point of the custom U/f curve at
the frequency defined by parameter
. See section
on page
38% of
U
N
0…120% of
U
N
V Voltage
1 = 1 V
2613 USER
DEFINED F2
Defines the second frequency point of the custom U/f curve. 20.0 Hz
0.0…599.0 Hz
Frequency
1 = 0.1 Hz
2614 USER
DEFINED U3
Defines the third voltage point of the custom U/f curve at the
frequency defined by parameter
See section
on page
47.5% of
U
N
0…120% of
U
N
V Voltage
1 = 1 V
2615 USER
DEFINED F3
Defines the third frequency point of the custom U/f curve.
25.0 Hz
0.0…599.0 Hz
Frequency
1 = 0.1 Hz
2616 USER
DEFINED U4
Defines the fourth voltage point of the custom U/f curve at
the frequency defined by parameter
. See section
on page
76% of
U
N
0…120% of
U
N
V Voltage
1 = 1 V
2617 USER
DEFINED F4
Defines the fourth frequency point of the custom U/f curve.
40.0 Hz
0.0…599.0 Hz
Frequency
1 = 0.1 Hz
2618 FW VOLTAGE
Defines the voltage of the U/f curve when frequency is equal
to or exceeds the motor nominal frequency (
). See section
on page
.
95% of
U
N
0…120% of
U
N
V Voltage
1 = 1 V
All parameters
No.
Name/Value
Description
Def/FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...