48 Actual signals and parameters
START/STOP
Reset along with the stop signal received through a
digital input, or from the control panel.
Note
: Do not use this option when start, stop and
direction commands are received through fieldbus
communication.
7
COMM
Fieldbus interface as the source for the fault reset
signal, that is the Control word 0301 FB CMD WORD
1 bit 4 (with ABB drives profile 5319 EFB PAR 19 bit 7)
(see ACS355 User’s manual (3AUA0000066143
[English]). The Control word is sent by the fieldbus
controller through the fieldbus adapter or embedded
fieldbus (Modbus) to the drive. For the Control word
bits, see sections DCU communication profile and
ABB drives communication profile in ACS355 User’s
manual (3AUA0000066143 [English]).
8
DI1(INV)
Reset through inverted digital input DI1 (reset on the
falling edge of DI1) or from the control panel
-1
DI2(INV)
See selection
-2
DI3(INV)
See selection
-3
DI4(INV)
See selection
-4
DI5(INV)
See selection
-5
1606
LOCAL LOCK
Disables entering local control mode or selects the
source for the local control mode lock signal. When the
local lock is active, entering the local control mode is
disabled (LOC/REM key of the panel).
DI2
NOT SEL
Local control is allowed.
0
DI1
Local control mode lock signal through digital input
DI1. Rising edge of digital input DI1: Local control
disabled.
Failing edge of digital input DI1: Local control allowed.
1
DI2
See selection
2
DI3
See selection
3
DI4
See selection
4
DI5
See selection
5
ON
Local control is disabled.
7
All parameters
No.
Name/
Value
Description
Def/ FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives Supplement ACS355 Solar pump inverter N827...
Page 4: ......
Page 10: ...10 Safety...
Page 14: ...14 Introduction...
Page 18: ...18 Operating principle and hardware description...
Page 30: ...30 Start up and controls...
Page 36: ...36 Program features...
Page 66: ...66 Actual signals and parameters...
Page 70: ...70 Fault tracing...
Page 76: ...76 Technical data...