14 Program features
Fast user set change
Totally 6 user sets and possibility change quickly between them. User can switch from
different ramp and controller values for different tools in case machine has several
tools.
Pararameter 0186 ACTIVE MACRO – shows which user set was last loaded,
updated after start inhibits are removed. Parameter 0186 changes to 0, when user
set load starts and drive is ready to start when parameter 0186 changes to loaded
user set value.
Related parameters are listed in the table below:
Settings
Parameter
Additional information
0186 ACTIVE MACRO
Shows which user macro is actively loaded.
1605 USER PAR SET CHG
Enables the change of the User parameter set through
a digital input.
1614 LOAD USER SET
Selects which user set will be loaded.
1615 SAVE USER SET
Selects which user set will be saved.
9902 APPLIC MACRO
Selects the application macro.