166 Parameters
Defines the maximum torque reference. Allows for
local limiting of the torque reference before it is
passed on to the torque ramp controller. For absolute
torque limiting, refer to parameter
.
300.0%
0.0…1000.0%
Maximum torque reference.
See par.
Selects torque reference source 1.
Two signal sources can be defined by this parameter
and
. A digital source
can be used
to switch between the two sources, or a
mathematical function (
)
applied to the two signals to create the reference.
Zero
None.
0
AI1 scaled
(see page
).
1
AI2 scaled
).
2
EFB ref1
(see page
).
8
EFB ref2
9
Motor potentiometer
22.80 Motor potentiometer ref act
(output of the
motor potentiometer).
15
PID
(output of the
process PID controller).
16
Frequency input
11.38
Freq in 1 actual value
(when DI3 or DI4 is used as
a frequency input).
17
No.
Name/Value
Description
Default
FbEq 16
1
0
0
AI
EFB
…
…
0
AI
EFB
…
…
MUL
SUB
ADD
MIN
MAX
Summary of Contents for ACS280