03 POWER ELECTRONICS AND CABINET FEATURES
3BHS206977 E01 REV H
ACS1000I AIR-COOLED
USER MANUAL
3.4.9
Inverter
The inverter converts the DC voltage to the required AC motor voltage and frequency.
Each phase of the three-phase inverter consists of a combination of four IGCTs and two NP
diodes for three-level switching operation. The output is switched between positive DC
voltage, neutral point (NP) and negative DC voltage. Hence, the drive can control the output
voltage and the frequency continuously from zero to maximum using direct torque control. For
more information, see “4.2.2.4 Direct torque control” on page 63.
Figure 3-12: Three-level voltage source inverter principle
3.4.10
Filter
The filter at the drive output reduces the harmonic content of the motor voltage and generates
a nearly sinusoidal motor-friendly voltage waveform. The filter also eliminates all high dv/dt
effects. Therefore, standard motors can be used, and voltage reflections in the motor cables
are eliminated.
Figure 3-13: Voltage and current waveforms at drive output
+
0
-
U=
Output voltage: 4.16 kV
Output frequency: 60 Hz
Summary of Contents for ACS1000i air-cooled
Page 1: ... MEDIUM VOLTAGE AC DRIVES ACS1000i air cooled User manual ...
Page 3: ...Contents ACS1000i air cooled User manual ...
Page 5: ... 01 About this manual 01 5 16 ...
Page 16: ......
Page 17: ... 02 Important safety information 02 17 28 ...
Page 28: ......
Page 29: ... 03 Power electronics and cabinet features03 29 56 ...
Page 57: ... 04 Control system 04 57 70 ...
Page 71: ... 05 Transportation storage and disposal05 71 78 ...
Page 78: ......
Page 79: ... 06 Mechanical installation 06 79 88 ...
Page 88: ......
Page 89: ... 07 Electrical installation07 89 104 ...
Page 105: ... 08 Commissioning 08 105 110 ...
Page 110: ......
Page 111: ... 09 Operation 09 111 124 ...
Page 125: ... 10 CDP control panel 10 125 148 ...
Page 149: ... 11 Preventive and corrective maintenance 11 149 172 ...
Page 173: ......