Actual signals and parameters
156
1) Percent of motor maximum speed / nominal torque / maximum process reference (depending on the
ACS800 macro selected).
2) The contents of these data words are detailed in chapter
04 ACTUAL SIGNALS
Signals for the Adaptive Program
2)
04.01
FAULTED INT INFO
A 16-bit data word. See section
in chapter
.
04.02
INT SC INFO
A 16-bit data word. See section
.
09 ACTUAL SIGNALS
Signals for the Adaptive Program
09.01
AI1 SCALED
Value of analogue input AI1 scaled to an integer value.
20000 = 10 V
09.02
AI2 SCALED
Value of analogue input AI2 scaled to an integer value.
20000 = 20
mA
09.03
AI3 SCALED
Value of analogue input AI3 scaled to an integer value.
20000 = 20
mA
09.04
AI5 SCALED
Value of analogue input AI5 scaled to an integer value.
20000 = 20
mA
09.05
AI6 SCALED
Value of analogue input AI6 scaled to an integer value.
20000 = 20
mA
09.06
DS MCW
Control Word (CW) of the Main Reference data set received from the
Master station through the fieldbus interface
0 ... 65535
(Decimal)
09.07
MASTER REF1
Reference 1 (REF1) of the Main Reference data set received from the
Master station through the fieldbus interface
-32768 …
32767
09.08
MASTER REF2
Reference 2 (REF2) of the Main Reference data set received from the
Master station through the fieldbus interface
-32768 …
32767
09.09
AUX DS VAL1
Auxiliary data set value 1 received from the Master station through the
fieldbus interface
-32768 …
32767
09.10
AUX DS VAL2
Auxiliary data set value 2 received from the Master station through the
fieldbus interface
-32768 …
32767
09.11
AUX DS VAL3
Auxiliary data set value 3 received from the Master station through the
fieldbus interface
-32768 …
32767
09.12
AUX DS VAL4
Auxiliary data set value 4 received from the Master station through the
fieldbus interface
-32768 …
32767
09.13
AUX DS VAL5
Auxiliary data set value 5 received from the Master station through the
fieldbus interface
-32768 …
32767
09.14
AUX DS VAL6
Auxiliary data set value 6 received from the Master station through the
fieldbus interface
-32768 …
32767
09.15
LCU ACT SIGNAL1
Line-side converter signal selected with parameter
LCU PAR1
SEL. A 16-bit data word.
09.16
LCU ACT SIGNAL2
Line-side converter signal selected with parameter
LCU PAR2
SEL. A 16-bit data word.
No.
Name/Value
Description
FbEq
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...