01 ABOUT THIS MANUAL
3BHS213401 E01 REV H
ACS1000 AIR-COOLED
USER MANUAL
- Appendix G - Signal and parameter table
The Signal and parameter table includes descriptions of actual signals, control and status
words, and control parameters and their default settings.
1.4
Terms and abbreviations
The following table lists terms and abbreviations you should be familiar with when using this
user manual. Some of the terms and abbreviations used in this user manual are unique to ABB
and might differ from the normal usage.
Term/Abbreviation
Definition
ACS1000A
ACS1000 air-cooled drive
AMC circuit board
Application and Motor Controller
The digital signal processor is the heart of the control system of the drive.
Cluster
A cluster is a synonym for a group of hardware modules of the drive
control system.
DDCS
Distributed drive control system
DDCS is an acronym for a serial communication protocol designed for data
transfer via optical fibers.
Drive
Short form for ACS1000 drive
Drive system
The drive system includes all equipment used to convert electrical into
mechanical power to give motion to the machine.
DriveBus
Communication link dedicated for ABB drives
DriveDebug
DriveDebug is part of ABB’s DriveWare® software tools for drives using the
DDCS communications protocol. DriveDebug runs on computers with
Windows® operating systems. DriveDebug is a specialist’s tool used to
diagnose, tune and troubleshoot ABB drives.
DriveWindow
DriveWindow is a DriveWare® product. DriveWindow is a 32 bit Windows®
application for commissioning and maintaining ABB drives equipped with
optical communication links.
Equipment
Frequency converter and related equipment
EMC
Electromagnetic compatibility
All measures to suppress electromagnetic disturbances caused by different
electrical equipment in the same electromagnetic environment, and to
strengthen the immunity of the equipment to such disturbances.
Ground
Earth
To ground
The conducting path (eg, conductor) between the electric equipment (eg,
frequency converter) and the earth. The electric equipment is connected to the
earth, eg, by a grounding set or a grounding switch.
INU
Inverter unit of the drive. The INU converts the DC voltage to the required AC
motor voltage and frequency.
IOEC module
The IOEC module is an active input and output device for digital and
analog signals.
Line voltage
RMS voltage of the main power supply of the drive
MCB
Main circuit breaker
The MCB is a major protection device of the drive and is the main connection
and disconnection point between the main power supply and the drive.
Molykote
Brand name for lubricants
PCB
Printed circuit board
Summary of Contents for ACS 1013-A1
Page 1: ... MEDIUM VOLTAGE AC DRIVES ACS1000 air cooled User manual ...
Page 3: ...Contents ACS1000 air cooled User manual ...
Page 5: ... 01 About this manual 01 3 14 ...
Page 16: ......
Page 17: ... 02 Important safety information 02 15 26 ...
Page 28: ......
Page 29: ... 03 Power electronics and cabinet features03 27 50 ...
Page 53: ... 04 Control system 04 51 66 ...
Page 68: ......
Page 69: ... 05 Transportation storage and disposal05 67 74 ...
Page 76: ......
Page 77: ... 06 Mechanical installation 06 75 82 ...
Page 84: ......
Page 85: ... 07 Electrical installation07 83 106 ...
Page 108: ......
Page 109: ... 08 Commissioning 08 107 112 ...
Page 115: ... 09 Operation 09 113 126 ...
Page 129: ... 10 CDP control panel 10 127 150 ...
Page 153: ... 11 Preventive and corrective maintenance 11 151 182 ...
Page 185: ......