122 Parameters
Storage parameter for controlling the relay outputs eg.
through the embedded fieldbus interface. To control the relay
outputs (RO) of the drive, send a control word with the bit
assignments shown below as Modbus I/O data. Set the target
selection parameter of that particular data (
…
)
to
. In the source selection parameter of
the desired output, select the appropriate bit of this word.
0000h
0000h…FFFFh
RO/DIO control word.
1 = 1
Displays the number of times relay output RO1 has changed
states.
-
0…4294967000
State change count.
1 = 1
Displays the number of times relay output RO2 has changed
states.
-
0…4294967000
State change count.
1 = 1
Displays the number of times relay output RO3 has changed
states.
-
0…4294967000
State change count.
1 = 1
11
Configuration of the frequency input.
Selects how digital input 5 is used.
Digital input
DI5 is used as a digital input.
0
Frequency input
DI5 is used as a frequency input.
1
Displays the value of frequency input 1 (via DI5 when it is
used as a frequency input) before scaling. See parameter
.
This parameter is read-only.
-
0 … 16000 Hz
Unscaled value of frequency input 1.
1 = 1 Hz
Displays the value of frequency input 1 (via DI5 when it is
used as a frequency input) after scaling. See parameter
This parameter is read-only.
-
-32768.000…
32767.000
Scaled value of frequency input 1 (DI5).
1 = 1
No.
Name/Value
Description
Def/FbEq16
Bit
Name
Description
0
RO1
Source bits for relay outputs RO1…RO3. See parameters
and
.
1
RO2
2
RO3
3
RO4
Source bits for relay outputs RO4…RO5 with a CHDI-01 or CMOD-01
extension module. See parameters
4
RO5
5…7
Reserved
8
DIO1
Source bit for digital output DO1 with a CMOD-01 extension module.
See parameter
9…15
Reserved
Summary of Contents for ACQ580
Page 1: ...ABB drives for water Firmware manual ACQ580 pump control program ...
Page 4: ... 2017 ABB Oy All Rights Reserved 3AXD50000035867 Rev C EN EFFECTIVE 2017 06 21 ...
Page 30: ...26 Start up control with I O and ID run ...
Page 40: ...36 Default configuration ...
Page 304: ...300 Parameters ...
Page 340: ...336 Additional parameter data ...