108 Parameters
05
Various run-time-type counters and measurements related to
drive maintenance.
All parameters in this group are read-only unless otherwise
noted.
On-time counter. The counter runs when the drive is
powered.
-
0…65535 d
On-time counter.
1 = 1 d
Motor run-time counter in full days. The counter runs when
the inverter modulates.
-
0…65535 d
Motor run-time counter.
1 = 1 d
Corresponding parameter to
in
hours, that is, 24 *
value + fractional part of a day.
-
0.0…
429496729.5 h
Hours.
10 = 1 h
Running time of the drive cooling fan. Can be reset from the
control panel by keeping Reset down for over 3 seconds.
-
0…65535 d
Cooling fan run-time counter.
1 = 1 d
Measured temperature of the control board
-
-100… 300 °C or °F Control board temperature in degrees Celsius or Fahrenheit. 1 = unit
Estimated drive temperature in percent of fault limit. The fault
limit varies according to the type of the drive.
0.0% = 0 °C (32 °F)
100.0% = Fault limit
-
-40.0…160.0%
Drive temperature in percent.
1 = 1%
No.
Name/Value
Description
Def/FbEq16