ABB ACQ580-P Series Supplement Installation Manual Download Page 3

Supplemental Installation Manual for ACQ580-Px

3

Safety instructions

Safety instructions

These are the safety instructions which you 
must obey when you install and operate the 
drive and do maintenance on the drive. If you 
ignore the safety instructions, injury, death or 
damage can occur.

Use of warnings and notes in this 
manual

Warnings tell you about conditions which can 
cause injury or death, or damage to the 
equipment. They also tell you how to prevent 
the danger. Notes draw attention to a partic

ul

ar 

condition or fact, or give information on a 
subject.

The manual uses these warning symbols: 

General safety in installation, 
start-up and maintenance

These instructions are for all personnel that 
install the drive and do maintenance work on it.

WARNING! 

Obey these instructions. If 

you ignore them, injury or death, or 

damage to the equipment can occur.

• Use safety shoes with a metal toe cap to 

avoid foot injury. Wear protective gloves and 
long sleeves. Some parts have sharp edges.

• Handle the drive carefully.

• Frames R5…R9: Lift the drive with a 

lifting device. Use the lifting eyes of the 
drive.

• Frames R5…R9: Do not tip the drive 

over. The drive is heavy and its center of 
gravity is high. An overturning drive can 
cause physical injury.

 

• Beware of hot surfaces. Some parts, such 

as heatsinks of power semiconductors, 
remain hot for a while after disconnection of 
the electrical supply.

• Keep the drive in its package or protect it 

otherwise from dust and burr from drilling 
and grinding until you install it.

• Vacuum clean the area below the drive 

before the start-up to prevent the drive 
cooling fan from drawing the dust inside the 
drive.

• Do not cover the air inlet and outlet when the 

drive runs.

• Make sure that there is sufficient cooling. 

See the 

ACQ580 Hardware Manual 

Electricity warning

 tells about hazards 

from electricity which can cause injury 

or death, or damage to the equipment. 

General warning 

tells about 

conditions, other than those caused by 

electricity, which can cause injury or death, 
or damage to the equipment.

Electrostatic sensitive devices 
warning

 tells you about the risk of 

electrostatic discharge which can cause 
damage to the equipment.

Summary of Contents for ACQ580-P Series

Page 1: ...ACQ580 Px Supplement Installation Manual for ACQ580 PC PD ACQ580 PC PD Packaged Drives with Disconnect 1 60 HP...

Page 2: ......

Page 3: ...dges Handle the drive carefully Frames R5 R9 Lift the drive with a lifting device Use the lifting eyes of the drive Frames R5 R9 Do not tip the drive over The drive is heavy and its center of gravity...

Page 4: ...art immediately after fault reset See parameters 20 02 Ext1 start trigger type and 20 07 Ext2 start trigger type in ACQ580 Pump control program firmware manual 3AXD50000035867 English When the control...

Page 5: ...and corner grounded TN systems North America in ACQ580 Hardware Manual Note For other systems connecting the internal EMC filter will reduce the conducted emission If the drive will be connected on a...

Page 6: ...rference In a multiple drive installation connect each drive separately to the protective earth PE bus of the power supply Make sure that the conductivity of the protective earth PE conductors is suff...

Page 7: ...C UDC and the grounding PE terminal is close to 0 V Install temporary grounding to the drive output terminals T1 U T2 V T3 W Connect the output terminals together as well as to the PE Start up and ope...

Page 8: ...f data installation of anti virus programs etc to protect the product the network its system and the interface against any kind of security breaches unauthorized access interference intrusion leakage...

Page 9: ...type of your drive refer to its construction code on either Serial number label attached on upper part of the top mounting plate between the mounting holes Type code label attached to the base frame o...

Page 10: ...ervicing the drive Failure to disconnect power may cause serious injury or death 1 Install wiring WARNING Metal shavings or debris in the enclosure can damage electrical equipment and create a hazardo...

Page 11: ...iring access from the bottom only The following figures show the layout and wiring connection points For drive control wiring see US Quick Start Guide 3AXD50000049128 Maintain appropriate separation o...

Page 12: ...emental Installation Manual for ACQ580 Px ACQ580 PC PD Disconnect Switch or Circuit Breaker Motor Ground Lug Fuses P3 P4 Input Ground Lug Input Terminals Motor Terminals Px1 3 Px12 3 Px1 4 Px12 4 ACQ5...

Page 13: ...UL NEMA Type 1 and 12 Motor Terminals Ground Lugs UL NEMA Type 1 and 12 ACQ580 Px 04A6 2 4 6 1 R1 10 62 in lbs 10 55 in lbs 10 0 7 ft lbs 2 50 in lbs ACQ580 Px 06A6 2 6 6 1 5 R1 ACQ580 Px 07A5 2 7 5 2...

Page 14: ...2 50 in lbs ACQ580 Px 03A0 4 3 1 5 R1 ACQ580 Px 03A5 4 3 5 2 R1 ACQ580 Px 04A8 4 4 8 3 R1 ACQ580 Px 07A6 4 7 6 5 R1 ACQ580 Px 012A 4 12 7 5 R1 ACQ580 Px 014A 4 14 10 R2 10 62 in lbs 8 55 in lbs 6 1 1...

Page 15: ...in lbs 10 55 in lbs 6 1 1 ft lbs 2 50 in lbs ACQ580 Px 03A9 6 3 9 3 R2 12 62 in lbs ACQ580 Px 06A1 6 6 1 5 R2 10 62 in lbs ACQ580 Px 09A0 6 9 7 5 R2 ACQ580 Px 011A 6 11 10 R2 ACQ580 Px 017A 6 17 15 R...

Page 16: ...es from other manufacturers can be used if they are 600V rated and meet the specifications given in the table Fuses with higher current rating than specified must not be used 208 Volt fuses for packag...

Page 17: ...0 Px 044A 4 44 30 R3 Class T 60A N A N A ACQ580 Px 052A 4 52 40 R4 Class T 80A N A N A ACQ580 Px 065A 4 65 50 R4 Class T 90A N A N A ACQ580 Px 077A 4 77 60 R4 Class T 100A N A N A 1 Px represents both...

Page 18: ...dle The operating handle can be padlocked in the OFF position padlock not supplied Enclosure options are UL NEMA Type 1 and UL NEMA Type 12 NEMA 1 and NEMA 12 The following is a typical power diagram...

Page 19: ...19 Supplemental Installation Manual for ACQ580 Px ACQ580 PC PD Dimensions P1 Type 1...

Page 20: ...Supplemental Installation Manual for ACQ580 Px 20 ACQ580 PC PD P1 Type 12...

Page 21: ...21 Supplemental Installation Manual for ACQ580 Px ACQ580 PC PD P2 Type 1...

Page 22: ...Supplemental Installation Manual for ACQ580 Px 22 ACQ580 PC PD P2 Type 12...

Page 23: ...23 Supplemental Installation Manual for ACQ580 Px ACQ580 PC PD P3 Type 1...

Page 24: ...Supplemental Installation Manual for ACQ580 Px 24 ACQ580 PC PD P3 Type 12...

Page 25: ...25 Supplemental Installation Manual for ACQ580 Px ACQ580 PC PD P4 Type 1...

Page 26: ...Supplemental Installation Manual for ACQ580 Px 26 ACQ580 PC PD P4 Type 12...

Page 27: ......

Page 28: ...3AXD50000459698REVA Effective 2019 09 01 Supersedes ABB Inc 16250 West Glendale Drive New Berlin WI 53151 USA Telephone 1 800 752 0696 Fax 1 262 785 0397 Internet www abb com drives...

Reviews: