Program features 137
Speed reference selection and scaling
Speed reference selection
Speed reference selection function sets the selection mode and priority of the speed
reference inputs. The selection mode can be set with parameter
SPEED REF
MODE.
MULTIPLE
– This mode can be used for multiple speed references. Up to eight
separate preset speed references can be programmed to the drive using parameters
in group
and can be selected using binary coded digital
inputs.
SEP HIGH PRI
– This mode can be used when high speed reference has priority. Up
to seven different speeds can be programmed to the drive and can be selected using
dedicated digital inputs. Each speed reference takes priority over the leveling speed.
SEP LEVL PRI
– This mode can be used when leveling speed reference has priority.
Up to seven different speeds can be programmed to the drive and can be selected
using dedicated digital inputs. The leveling speed reference, takes priority over all
other speed references when enabled through one of the digital input terminals.
The function calculates the final speed reference to be used by the elevator in the
different elevator operation modes, depending on the settings in parameters
SPEED REF MODE,
SPEED REF SEL2,
SPEED REF SEL3, and
SPEED REF SEL4.
* The speed1 reference is fixed to a constant value 0 m/s. It can be used for stopping the elevator.
Speed references
available
Elevator operation mode
Speed 1*, 2, or 3
Normal travel mode
Nominal speed
Normal travel mode
Medium speed
Normal travel mode
Leveling speed
Normal travel mode, when the leveling command is active
Releveling speed
Reveling mode
Inspection speed
Inspection mode or normal travel mode, depending on which mode is active
Evacuation speed
Evacuation mode
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...