background image

ABB-Welcome

Technical data

  |

— 11 —

Pos: 76 /Di nA4 - A nleitu ngen  Onlin e/Ueb ersc hrift en/1 ./T echnisc he D aten  @ 18 \mo d_1 302 615 863 001 _15. docx @  10 341 6 @ 1  @ 1

5

Technical data

Pos: 77 /Di nA4 - A nleitu ngen  Onlin e/In halt/KNX/Do orEnt ry/83 220 -AP-xxx/ Tech nische  Date n -  832 20-AP-x xx @ 1 8\m od_ 130 321 285 4559 _15 .docx  @ 1 037 05 @   @ 1

5.1

Overview table

Designation

Value

Operating temperature

-25

 - +55

Storage temperature

-40

 - +70

Protection

IP 44

Single-wire clamps

2 x 0.28 mm² - 2 x 0.75 mm²

Fine-wire clamps

2 x 0.28 mm² - 2 x 0.75 mm²

Bus voltage

20-30 V DC

Product dimensions

83110: 68 mm x 126 mm x 31 mm

83111: 68 mm x 50 mm x 24 mm

Pos: 78 /B usch-J aeg er (Neus truk tur )/M odul -Strukt ur/O nline -Doku me ntatio n/Steu er mod ule - Onlin e-Dok ume ntati on ( -- > F ür alle Dok ume nte  <- -)/ +++ ++ ++ +++ ++ S eiten umb ruch  + +++ ++ ++ +++ + @  9\m od_ 126 8898 668 093 _0. docx @  521 49  @  @  1

Summary of Contents for ABB-Welcome

Page 1: ...Online Inh alt KNX Doo rEntry 832 20 AP xxx Tit elblat t 832 20 AP xxx ABB 1 9 m od_ 132 3249 806 476 _15 docx 11 108 4 1 83110 500 Audio integration unit 83111 500 Extension unit 83501 101 500 Camera integration module E nde der Liste für Tex tma rke C over ...

Page 2: ...1 Safety 3 2 Intended use 3 3 Environment 4 3 1 ABB devices 4 4 Operation 5 4 1 Control elements 5 4 2 Setting address 7 4 2 1 physical address mode 7 4 2 2 Mapping address mode 8 4 2 3 To set function of 1st 2nd button 9 5 Technical data 11 5 1 Overview table 11 6 Mounting Installation 12 6 1 Requirements for the electrician 12 6 2 General installation instructions 13 E nde der Liste für Tex tma ...

Page 3: ...A F Bestim mun gsge mä ßer Geb rau ch 18 mod _13 027 6332 131 6_1 5 do cx 1034 83 1 1 2 Intended use Pos 9 DinA4 Anl eitun gen Online Inh alt KNX Doo rEntry 832 20 AP xxx Besti mmu ngsg em aesse r Ge bra uch 83 220 AP xxx 500 2 0 mo d_1 324 561 168 699 _15 docx 11 272 8 1 The audio module assembly serves as voice and reception device for installing in a suitable door and letter box system The 8311...

Page 4: ...riate collecting facility Pos 12 Di nA4 A nleitu ngen Onlin e Ueb ersc hrift en 2 ABB Gera ete 19 mo d_1 323 162 843 832_ 15 docx 11 087 5 2 1 3 1 ABB devices Pos 13 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Umw elt Für all e Doku me nte Hinweis e Hinw eis U mwelt ABB Elektro ger äte 19 mo d_1 3231 627 458 39_ 15 d ocx 110 867 1 All packaging materials and devices fro...

Page 5: ...0 mod _13 232 6022 055 9_1 5 do cx 1 116 47 3 1 Pos 21 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry 83 220 AP xxx Be dienel eme nte 8 322 0 AP xxx 18 mo d_1 3032 128 536 05_ 15 d ocx 103 673 1 No Functions 1 Terminals to connect the mechanical buttons 2 Connecting terminal for common dimensions 3 Relay out fix as 3s 4 Bus 5 Connection for camera module 6 Connection for extension unit 7 Mic...

Page 6: ...ra with automatic day night switchover and infrared LEDs to illuminate the night shots Installed heating to keep the lens free of condensation Vertical horizontal detection angle 86 67 Setting angle horizontal vertical 15 mechanically adjustable Consumer units 4 Temperature range Device 25 C 55 CC Pos 22 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin ...

Page 7: ...3 3 1 Pos 72 Di nA4 A nleitu ngen Onlin e In halt KNX Do orEnt ry Bedie nun g Abschl usswide rsta nd s etzen 83 220 AP xxx 19 mod _13 1072 339 236 9_1 5 do cx 1 078 41 1 4 2 1 physical address mode 1 The address of each button is generated automatically Button 1 is 01 button 2 is 02 etc 2 The start address of button 1 can be shifted by use of the last 2 potentiometers For example the last 2 rotary...

Page 8: ...dressing mode otherwise it will work in the physical addressing mode start 1 Adjust rotary switches to 000 and hold any button for 3 s to enter into programming mode beep 2 Adjust rotary switches to the required value like 003 and hold dedicated button for at least 1 3s until hear the prompt tone beep continue to program End 3 Adjust rotary switches to X00 X address of outdoor station and hold any...

Page 9: ... Welcome Operation 9 4 2 3 To set function of 1st 2nd button 4 2 3 1 Function setting 0 1st button 0 1 hold 1st button for 3 s 0 0 9 hold 1st button for 3 s hold 1st button for 3 s hold 1st button for 3 s ...

Page 10: ...ons are offset 4 2 3 3 1st 2nd button setting in mapping address mode After set the 1st 2nd button the address of the remain buttons are fixed Pos 75 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ule Onlin e Dok ume ntati on Für alle Dok ume nte S eiten umb ruch 9 m od_ 126 8898 668 093 _0 docx 521 49 1 ...

Page 11: ...5 docx 1 037 05 1 5 1 Overview table Designation Value Operating temperature 25 55 Storage temperature 40 70 Protection IP 44 Single wire clamps 2 x 0 28 mm 2 x 0 75 mm Fine wire clamps 2 x 0 28 mm 2 x 0 75 mm Bus voltage 20 30 V DC Product dimensions 83110 68 mm x 126 mm x 31 mm 83111 68 mm x 50 mm x 24 mm Pos 78 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Steu er mod ...

Page 12: ...f Pos 81 B usch J aeg er Neus truk tur M odul Strukt ur O nline Doku me ntatio n Siche rheit Fü r alle D oku ment e War nhinweis e Siche rheit Fachk enn tnisse 18 mo d_1 302 774 384 017_ 15 docx 10 356 4 2 1 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers...

Page 13: ...ng wires of the door openers and wires of the system bus Avoid bridges between different cable types Use only two wires for the system bus in a four core or multi core cable When looping never install the incoming and outgoing bus inside the same cable Never install the internal and external bus inside the same cable For optimum tone quality ensure that the module is seated correctly Press the mic...

Page 14: ...Tex tma rke Ba ckcove r We reserve the right to at all times make technical changes as well as changes in the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations cont...

Reviews: