Operation Manual / A200-L
5 Monitoring during operation / 5.1 Oil pressure, oil temperature
© Copyright 2021 ABB. All rights reserved.
HZTL4036_EN
Rev.T
December 2021
Status for operation
Oil temperature at the inlet
T
oil,inlet
[°C]
Not admissible
→
do not start engine (before start: preheat
oil)
< 30
Table 8: Lubricating oil temperature at the inlet
Lubricating oil temperature at the outlet
The oil temperature at the outlet is mainly dependant on:
¡
Lubricating oil temperature and pressure at the oil inlet
¡
Engine load and turbocharger speed
¡
Exhaust gas temperature
The maximum admissible oil temperature at the outlet is listed in the following table. The
specified oil outlet temperature is to be considered as alarm value for the turbocharger op-
eration and must be monitored according to the current regulations.
Fig. 11: Oil temperature at the outlet
Status for operation
Oil temperature at the inlet
T
oil,inlet
[°C]
Oil temperature at the outlet
T
oil,outlet
[°C]
Admissible
45
≤
110
Admissible
80
≤
125
Temporarily admissible
→
alarm
45
> 110
Temporarily admissible
→
alarm
80
> 125
Not admissible
→
stop engine
45
> 120
Not admissible
→
stop engine
80
> 135
Table 9: Lubricating oil temperature at the outlet
If the turbocharger has been operated for a longer period of time outside the admissible
range, ABB Turbocharging recommends having the turbocharger inspected by an ABB Tur-
bocharging Service Station.
Page
35
/
145