Operation Manual / 4 Product description / A150-M56/66/57/67 -
A155-M..
6 Periodic maintenance work / 6.2 Cleaning the compressor during
operation
© Copyright 2020 ABB. All rights reserved.
HZTL4032_EN
Rev.P
March 2020
6.2.3
Cleaning method
Cleaning method and operating state
The compressor is cleaned during operation using the wet cleaning method. This is carried
out at an engine load of 50 … 85%.
This cleaning method is tested and approved by ABB Turbocharging.
V-engines
On V-engines with several turbochargers per engine, parallel cleaning of both turbochargers
is recommended. This cleaning process is faster and reduces the risk of surging of the tur-
bocharger.
Sequential charging
With sequential charging, it must be made sure especially after operating periods in the
lower range of performance that both turbocharger compressors are cleaned.
6.2.4
Function and safety of wet cleaning
CAUTION
Volume of water
Uncontrolled volumes of water can damage the turbocharger and the en-
gine.
u
Never connect the water connection directly to a water pipe or a bigger
metering container than the one specified by ABB Turbocharging.
WARNING
Danger due to pressure vessels
Personal injury can occur if the locally applicable legal regulations on peri-
odic inspections of the pressure vessels are not complied with.
u
The locally applicable legal regulations regarding periodic checks of the
pressure vessels must be observed.
u
Do not use pressure vessels that are defective.
CAUTION
Corrosion and deposits when cleaning
Salt water and cooling water treatment substances damage and adversely
affect turbocharger parts.
u
Never use salt water, but only pure water for cleaning.
Page
41
/
171