Adjusting the device
Pos : 71 /DinA4 - Anl eitungen Onli ne/Ueberschrif ten/ 3. /Absc hlus s widerst and @ 19\ mod_1321958079906_15.doc x @ 110083 @ 3 @ 1
Pos : 72 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/Bedienung/Absc hl uss widerst and setzen 83220-AP- xxx @ 19\ mod_1310723392369_15.doc x @ 107841 @ @ 1
Fig. 2:
Pos : 74 /DinA4 - Anl eitungen Onli ne/I nhalt/ KN X/D oor Entr y/Bedienung/Mast er/Sl ave Schalt er s etz en 83220-AP- xxx @ 19\ mod_1310723320966_15. doc x @ 107833 @ @
1.
Station
Selector switch to set the address of default outdoor station.
2.
X10 X1
Selector switches to set the address (tens and units digits) of the indoor station.
X100 X200
Se
t through “light” button.
3.
Master /Slave function
Only one indoor station in each apartment must be set as "Master" (Switch should
be set as 'M/S on'). All additional indoor stations in the same apartment must be
set as "Slave" (Switch should be set as 'M/S off').
4.
Terminal resistor
In video installations or mixed audio and video installations, the Switch must be
set as 'RC on' on the last device of the line.
5.
a b
= Bus connection
= Door bell connection