General data
Device description
General standards
•
IEC 60255-21-2 class 1
•
IEC 60255-21-3 class 1
•
EN 50125-3 class T1 and T2
Electromagnetic compatibility (EMC) tested
according to
•
IEC 61000-6-1
•
IEC 61000-6-2
•
IEC 61000-6-3
•
IEC 61000-6-4
•
•
EN 50121-4
Environmental conditions - climatic
Nominal operating temperature range
EN 60068-2-1, EN 60068-2-2, EN 60068-2-14
-40 °C ... 80 °C
Relative humidity
EN 60068-2-30
5... 95 %
(non condensing)
Railway applications
EN 50125-3
climatic class T1 and T2
Environmental conditions - mechanical
Vibration sinusoidal, Test Fc , IEC
60068-2-6
3 mm (3...9 Hz)
10 m/s² (9...200 Hz)
1 octave/ min, 10 cycles per axis
ETSI EN 300 019-1-3 class 3.4
IEC 60721-3-3 class 3M5
3.5 mm (3...9 Hz)
10 m/s² (9...35 Hz)
1 octave/ min, 1 cycle per axis
IEC 60255-21-3 class 1
3 mm (3...9 Hz)
10 m/s² (9...200 Hz)
15 m/s² (200...500 Hz)
1 octave/ min, 10 cycles per axis
IEC 60870-2-2 class Bm
0.035 mm (10 Hz...60 Hz)
5 m/s² (60 Hz...150 Hz)
1 octave/ min, 1 cycle per axis
IEC 60255-21-1 class 1
Shock and Bump, Test Ea, IEC
60068-2-27
50 m/s², 30 ms
3 shocks per direction
250 m/s², 10 ms
4 shocks per direction
IEC 60721-3-3 class 3M5
150 m/s², 11 ms
3 shocks per direction
IEC 60255-21-2 class 1
IEC 60870-2-2 class Bm
22
1KGT151042
V000 1