U N IVE R SA L S E N SOR ACCE SSORY 

¾

  I N

  |  O P EN C H A N N EL A N D O P EN TA N K M O U N T I N G K I T  |  I N/A N A I N S T/0 49 - EN R E V. A

…3  Assembly installation

A

B

C

D

E

F

G

G

H

I

J

L

M

N

O

P

Q

K

Figure 1  Open channel and open tank mounting assembly installation

Summary of Contents for 3KXA494400L005

Page 1: ...006 open channel and open tank mounting kits used with any in sensor The procedure must be carried out by a trained technician Requirements Table 1 Tools required Part number Description Quantity 6 mm OD semirigid tubing as required Flat bladed screwdriver 1 Mallet rubber or hide 1 Adjustable spanner 1 For more information Further information is available from www abb com analytical or by scanning...

Page 2: ...ipment Failure to do so could result in bodily harm or damage to the equipment 2 Identification The contents are shown in Table 2 and Table 3 Table 2 Open channel and open tank mounting assembly Description Part number Open channel and open tank mounting assembly comprising baseplate clamp including locking knobs channel and 2 channel bungs fixings 3KXA494400L0005 This instruction Open channel and...

Page 3: ...ed lock nut M 10 Pass EZLink sensor cable connector N and sensor cable O through the hole in sensor chain mounting adaptor L and feed entire cable O and chain I length through 11 Screw sensor body P onto sensor chain mounting adaptor L using PTFE tape to seal NOTICE Do not overtighten 12 Feed the cable chain under channel clamp arrangement D and pull through so that the chain and cable lengths are...

Page 4: ...L SENSOR ACCESSORY IN OPEN CHANNEL AND OPEN TANK MOUNTING KIT IN ANAINST 049 EN REV A 3 Assembly installation A B C D E F G G H I J L M N O P Q K Figure 1 Open channel and open tank mounting assembly installation ...

Page 5: ...ANAINST 049 EN REV A 5 Dimensions in mm in Figure 2 Open channel mounting kit dimensions 3 0 1 40 1 57 200 7 87 130 5 12 60 2 36 10 0 4 54 2 13 250 9 84 400 15 75 1000 39 37 uncut customer can cut to required length 4 slots suitable for 8 mm dia bolts or imperial equivalent ...

Page 6: ...h through 3 Screw sensor body G onto sensor chain mounting adaptor B using PTFE tape to seal NOTICE Do not overtighten 4 When the required chain cable length has been determined secure the chain onto second threaded stud using locknut supplied NOTICE Ideally the measuring end of the sensor should be a minimum of 300 mm 12 in below the free surface of the liquid being monitored 5 Gently lower the s...

Page 7: ...UNIVERSAL SENSOR ACCESSORY IN OPEN CHANNEL AND OPEN TANK MOUNTING KIT IN ANAINST 049 EN REV A 7 C B D E F G A Figure 3 Kit installation ...

Page 8: ...rring to Figure 4 1 Connect the sensor mounted cleaning adaptor A to the sensor thread B until air port lines up with membrane 2 Connect the push fit connector C and air supply using 6 mm OD semirigid tubing customer supplied Refer to OI EZCLEAN EN for instructions to configure the EZClean air blast system A B C C Figure 4 Cleaning kit ...

Page 9: ...UNIVERSAL SENSOR ACCESSORY IN OPEN CHANNEL AND OPEN TANK MOUNTING KIT IN ANAINST 049 EN REV A 9 Acknowledgements EZLink is a trademark of ABB Limited ...

Page 10: ...10 UNIVERSAL SENSOR ACCESSORY IN OPEN CHANNEL AND OPEN TANK MOUNTING KIT IN ANAINST 049 EN REV A Notes ...

Page 11: ...UNIVERSAL SENSOR ACCESSORY IN OPEN CHANNEL AND OPEN TANK MOUNTING KIT IN ANAINST 049 EN REV A 11 Notes ...

Page 12: ...al errors or possible lack of information in this document We reserve all rights in this document and in the subject matter and illustrations contained therein Any reproduction disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB ABB 2022 3XKA494404R3101 ABB Measurement Analytics For your local ABB contact visit www abb c...