Commissioning
Product manual 2TMD042100D0003
│
34
During setting, please swipe the same admin card.
Function
Action
Unlock indicator
Exit settings
Swipe admin card 1x or no
cards swiped within 15 seconds
--
Function
Action
Unlock indicator
Open a door
Swipe the enrolled keycard
Green
Reset to factory default
Press and hold the 1st button for
3 s to enter configuration mode.
3 LED: flash green
Press and hold the 1st button for
10 s to reset to factory default.
3 LED: OFF
Reboot the device
Door open LED: red, green,
orange cycle flash
Technical data of IC card
Work frequency
Standard
13.56 MHz
Mifare one S50/S70, Mifare desfire EV1/EV2
Note
A maximum of 64 IC cards can be supported by mini outdoor station.
2. Card management on management software
Please see the "ABB i-HD management software" product manual for more details.