2TLC010088M0201
Rev.A
24
Safety-related characteristic data and
Conformity
Safety Classification for Guard position and lock monitoring :
These values are correct provided the OSSD outputs are connected to a suitable logic device,
for example, ABB Electrification Sentry safety relays. Both channels must be used.
Characteristic data according to IEC 62061:2021 (used as a subsystem)
Safety Integrity Level
SIL 3
PFH (1/h)
1.0 E-09 (Corresponds to 1% of SIL3)
PFD (Av.)
8.7 E-05 (Corresponds to 9% of SIL3)
Proof Test Interval T1
20 a
Characteristic data according to EN ISO 13849-1:2015
Performance Level
e
Category
Cat 4.
MTTF
D
771 a
Diagnostic Coverage DC
High
Certifications
TÜV, cULus
Information regarding UL Standards: Type 1 enclosure. Use Class 2 power supply or equivalent.
Maximum temperature 40°C.
Use 16-28AWG copper conductors (rated 90°C). Terminal Torque 6 lb ins. (0.7 Nm).
Intended for same polarity use. Safety Circuits (11-12 & 21-22) 24 V DC 200 mA max.
Use one polymeric conduit connection. Not suitable for connection to rigid metal conduit.
Earth bonding terminal inside metal enclosures (if required). Use 16-12AWG conductors.
Summary of Contents for 2TLA050007R0602
Page 15: ...2TLC010088M0201 Rev A 15 Dimensions MKey9RF MKey8RF ...
Page 16: ...2TLC010088M0201 Rev A 16 MKey8ZRF MKey10RF MKey10RFER ...
Page 18: ...2TLC010088M0201 Rev A 18 MKey10RF ER Die cast handle same for Left and Right versions ...
Page 20: ...2TLC010088M0201 Rev A 20 Slilde bolt MKey10RF ER same for Left and Right versions ...
Page 25: ...2TLC010088M0201 Rev A 25 9 Declaration of conformity ...
Page 26: ...2TLC010088M0201 Rev A 26 ...