background image

  

 

 

DALI potentiometer for broadcast 
operation 

 

 

 

 

 
 

 
 
  | 1473-1-7978 

— 2 —

   

Pos: 4 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Inhaltsverzeichnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_1320649044386_15.docx @ 109653 @  @ 1 

 

 

1

 

Safety ....................................................................................................................................................................... 3

 

2

 

Intended use ............................................................................................................................................................ 3

 

3

 

Environment ............................................................................................................................................................. 3

 

4

 

Operation ................................................................................................................................................................. 4

 

4.1

 

Dimming speed ....................................................................................................................................... 4

 

4.2

 

Adjusting the basic brightness ................................................................................................................ 4

 

4.3

 

Deleting the basic brightness .................................................................................................................. 5

 

4.4

 

Activation with memory function .............................................................................................................. 5

 

4.5

 

Changing the switch-on brightness ......................................................................................................... 5

 

4.6

 

Deleting the switch-on brightness ........................................................................................................... 6

 

4.7

 

Adjusting the colour of the light for orientation ........................................................................................ 6

 

4.8

 

Changing the power-on level (optional setting): ...................................................................................... 7

 

4.9

 

Operation at several control points ......................................................................................................... 7

 

5

 

Technical data.......................................................................................................................................................... 8

 

6

 

Setup and function ................................................................................................................................................... 9

 

6.1

 

Features of function and equipment ........................................................................................................ 9

 

6.2

 

Possible combinations ............................................................................................................................ 9

 

7

 

Installation and electrical connection ..................................................................................................................... 10

 

7.1

 

Requirements for the electrician ........................................................................................................... 10

 

7.2

 

Mounting ............................................................................................................................................... 11

 

7.3

 

Inserting optical fibres ........................................................................................................................... 11

 

7.4

 

Electrical connection ............................................................................................................................. 12

 

 

=== Ende der Liste für Textmarke TOC === 

 

Summary of Contents for 2117 U-500

Page 1: ... operation Pos 2 Neustruktur Modul Struktur Online Dokumentation Titelblätter Dimmer Titelblatt 2117 U 23 mod_1336123192553_15 docx 208974 1 DALI potentiometer for broadcast operation Insert 2117 U 500 Insert 2117 11 U 500 Ende der Liste für Textmarke Cover ...

Page 2: ...tivation with memory function 5 4 5 Changing the switch on brightness 5 4 6 Deleting the switch on brightness 6 4 7 Adjusting the colour of the light for orientation 6 4 8 Changing the power on level optional setting 7 4 9 Operation at several control points 7 5 Technical data 8 6 Setup and function 9 6 1 Features of function and equipment 9 6 2 Possible combinations 9 7 Installation and electrica...

Page 3: ...C 62386 e g DALI electronic ballast units No other DALI controllers must be combined with DALI potentiometer 2117 U 500 and 2117 11 U 500 Pos 11 1 Neustruktur Modul Struktur Online Dokumentation Überschriften Für alle Dokumente 1 Ebene U Z Umwelt 18 mod_1302614158967_15 docx 103383 1 1 3 Environment Pos 11 2 Neustruktur Online Dokumentation Sicherheitshinweise und Hinweise Für alle Dokumente Hinwe...

Page 4: ..._1331210626890_15 docx 202059 222222222 1 4 1 Dimming speed Fig 1 Slow rotation of the control element Fine setting with up to 254 brightness levels Fig 2 Fast rotation of the control element Large brightness changes in order to reach the desired setting quickly 4 2 Adjusting the basic brightness Fig 3 Turn the control element slowly to adjust the basic brightness 1 Switch the lighting on 2 Adjust...

Page 5: ...rightness set memory function The manual adjustment of the switch on brightness overwrites this function 4 5 Changing the switch on brightness Fig 5 To adjust a fixed switch on brightness carry out the following steps 1 Switch the lighting on 2 Adjust the brightness 3 Double click fast on the control element The load flashes twice after the setting has been made The defined brightness overwrites t...

Page 6: ...last brightness before deactivation 4 7 Adjusting the colour of the light for orientation Fig 7 To change the colour of the light for orientation carry out the following steps 1 Switch the lighting load off 2 Press the control element keep it pressed and turn it quickly back and forth three times 3 Release the control element The light for orientation flashes 3 times 4 Select the colour of the LED...

Page 7: ...ss the control element for 10 seconds After the setting has been made the lighting load flashes once and the light for orientation 3 times When the mains voltage returns the DALI control unit now switches on at the last brightness set 4 9 Operation at several control points The DALI control units can be operated from several control points In the process the brightness of the last operated potenti...

Page 8: ...ronic Maximum connectable DALI operating devices dependent on an external power supply 64 Operating temperature 0 C 35 C Protective class IP20 Maximum cable length in the system 300 m Number of colours of the light for orientation 18 Off 2117 11 U 500 Nominal voltage 230 V 10 50 60 Hz Power consumption 7 15 mA Open circuit voltage output voltage 15 5 V Maximum drawn current 75 mA Protective circui...

Page 9: ...f connected DALI operating devices e g DALI electronic ballast units DALI LED modules etc They operate in broadcast mode uniform actuation of all DALI control units in the system For DALI potentiometer 2117 U 500 an additional external DALI power supply is required Device 2117 11 U 500 has its own power supply Pos 22 Neustruktur Modul Struktur Online Dokumentation Überschriften Für alle Dokumente ...

Page 10: ...line Dokumentation Sicherheitshinweise und Hinweise Für alle Dokumente Warnhinweise Sicherheit Fachkenntnisse 23 mod_1336559183027_15 docx 209179 2 1 7 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system I...

Page 11: ...struktur Modul Struktur Online Dokumentation Montage alle Geräte Montage UP Dosen DIN 49073 1 21 mod_1331210080219_15 docx 202029 1 The device must only be installed in suitable flush mounted sockets DIN 49073 1 Pos 33 Neustruktur Modul Struktur Online Dokumentation Montage Dimmer Montage 2117 21 mod_1331210177831_15 docx 202044 2 1 7 3 Inserting optical fibres Fig 9 Insert the optical fibre direc...

Page 12: ...entation Überschriften Für alle Dokumente 2 Ebene A F Elektrischer Anschluss 21 mod_1328177051724_15 docx 138042 2 1 7 4 Electrical connection Pos 36 Neustruktur Modul Struktur Online Dokumentation Anschluss Dimmer Anschluss 2117 21 mod_1331205283908_15 docx 202014 1 Fig 10 No Function 1 DALI power supply 2 2 DALI operating device 3 2117 U 500 ...

Page 13: ...e device is then supplied with current directly from the bus Up to 3 DALI potentiometers 2117 11 U 500 and 5 DALI potentiometers 2117 U 500 can be operated in parallel In the process observe the maximum permissible power consumption When DALI operating devices e g electronic ballasts are connected the specifications of the respective manufacturer must be observed The DALI control line and mains li...

Page 14: ...9909 Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therei...

Reviews: