Operation Manual / TPS44-H.. - TPS52-H..
10 Dismantling and fitting / 10.17 Installing the gas outlet casing
© Copyright 2021 ABB. All rights reserved.
HZTL4037_EN
Rev.G
June 2021
10.17
Installing the gas outlet casing
Fig. 45: Fitting the gas outlet casing
Product
Size
Tightening torque [Nm]
TPS44
M8
25 Nm
TPS48
M8
25 Nm
TPS52
M10
50 Nm
Table 41: Tightening torque (51008)
1. Coat thread of studs (51008) with high-temperature grease.
2. Align the casing position of the gas outlet casing (61001) to the marking.
3. Position the gas outlet casing and fit with two hexagon nuts (51009) in the upper area.
4. Fit the remaining hexagon nuts (51009), then tighten all the screws. Observe tightening
torque.
Page