CAPACITY TABLE
SIZE
FLOW RANGES
0 TO VALUE TABULATED
CAPACITY SETTINGS
(IF NOT SPECIFIED
BY CUSTOMER)
MINIMUM
MAXIMUM
Inches
mm
gpm
m
3
/h
gpm
m
3
/h
gpm
m
3
/h
30
36
42
48
54
60
66
72
78
750
900
1100
1200
1400
1500
1700
1800
2000
3630
5370
7400
9400
12100
14800
17900
20200
25600
810
1200
1650
2100
2700
3300
4000
4500
5700
81000
120000
165000
210000
270000
330000
400000
450000
570000
16200
24000
33000
42000
54000
66000
80000
90000
114000
22000
32000
45000
60000
70000
90000
110000
120000
150000
5000
7000
10000
12000
16000
20000
24000
27000
35000
METER CAPACITY (10m/sec)
Each 10DX3111 meter in sizes 30" through 78" is calibrated at the factory and the meter capacity
unique to the individual meter is indicated on a tag attached to the side of the meter body. See the
instructions for the converter in the Converter/Driver for details on programming the converter to
use this meter capacity. Note that this is truly a PROGRAMMABLE factor; do NOT follow con-
verter instructions for using a "constant meter factor".
The range requested by the customer is also marked on the tag attached to the meter.
FIGURE 1-2 . CONDUCTIVITY GRAPH
10DX3111G INSTRUCTION MANUAL
1-8