1.2.2 Model 10DX3311E
10DX3311 E _ _ _ _ _ _ _ _ _ _ 1 _ 2 X _ A _ _ _ _
Engineering Reference
Obstructionless Integral Magnetic
Flowmeter
Design Level
Integral with 50XM1000 Converter
Electronics
E
Meter Lay Length
Short Form (WMAG)
D
Replacement for 10D1419 & 10D1465
E
Replacement for 10D1435
F
Other
Z
Liner Material
Hard Rubber
A
Polyurethane
D
PTFE TEFLON
E
Neoprene
L
TEFZEL
N
Size
mm (inches)
15 (1/2)
07
25 (1)
09
40 (1-1/2)
11
50 (2)
12
80 (3)
14
100 (4)
15
150 (6)
17
200 (8)
18
250 (10)
19
300 (12)
20
Flange Standard Pressure Rating
DIN PN 10
C
DIN PN 16
D
DIN PN 25
E
DIN PN 40
F
ANSI Class 150
P
ANSI Class 300
Q
Flange Material
Carbon Steel
1
304 Stn. Steel
2
Protector Plate (TEFLON Liner only)
None Required
A
316 Stn. Steel
B
HASTELLOY C
E
Electrode Type
Flush
2
Bullet Nose
3
Flush (Slurry Service)
7
Electrode Material
316 Stn. Steel
B
HASTELLOY B
C
HASTELLOY C
D
Titanium
E
Tantalum
F
Platinum/Iridium
H
Zirconium
L
Certification
General Purpose
A
FM Approved-Nonincendive for Cl
I
, Div 2, Gp A,B,C & D; Electrodes
Intrinsically Safe for CI
I
, Div 1, Gp A,B,C & D; Outdoor Hazardous
Locations, NEMA 4X. Dust-Ignitionproof Cl
II
, Div 1, Gp E,F & G: Suitable
for Cl
III
, Div 1, Accidental Submergence, 30ft H
2
O/48h (9m H
2
O/48h)
K
Series 10DX3000 Magnetic Flowmeter Instruction Manual
1-6