DAY 1-180: A unit that fails between 1 and 180 days after sale will be repaired at no cost 
to the user. This may involve paying for repair services, parts, transportation, and repair 
consumables, depending on how and where the repair is carried out. 

 

• 

DAY 181-365: A unit that fails between 31 and 365 days after sale will have parts and 
labor charges covered under warranty, but transportation charges are to be paid by the 
customer. Transportation costs include travel charges by repair personnel, or shipping 
charges to move the unit to and from a repair location. 

 

• 

YEAR 2-5: A unit that fails in the second through fifth year inclusive will be covered for 
the compressor, evaporator coil and condenser coil – parts only. No labor will be 
provided. The customer will be responsible for the cost of the repair (less the covered 
parts), any transportation involved, as well as the shipping cost of having the parts sent 
to them.  

 

 
ATI will not be responsible for: 
 

1.  Useful filter life / replacement filters. 
2.  Damage due to failure to perform normal maintenance as outlined in the Instruction 

Manual. 

3.  Failure to start due to voltage conditions, blown fuses, open circuit breakers, or any 

other damages due to the inadequacy or interruption of electrical services. 

4.  Damage or repairs needed as a consequence of any misapplication, abuse, neglect, 

unauthorized alteration, improper servicing, or operation, including operation outside the 
voltage and frequency limitations as stated on the unit rating plate. 

5.  Damage as a result of flooding (immersion), fires, lightning, freezing of residual water, 

corrosive environment, or other conditions beyond the control of ATI. 

6.  Reimbursement for warrantable replacement parts not supplied by ATI. 
7.  Shipping damage, or damage as a result of abuse in transporting the unit. 

 

ATI does not warrant that the goods sold are merchantable or fit for any 
particular purpose. ATI makes no warranties other than as stated in this paragraph. 
 
All other warranties, guaranties, or representations, express or implied, by operation of 
law or otherwise, are expressly disclaimed. 
 

Goods found by ATI to be defective or not to conform to specification shall 
upon return be replaced or repaired by ATI without any additional charges, or, at ATI’s option, 
ATI may refund the purchase price of such goods. Where applicable, as indicated above, ATI 
will pay return transportation charges on returned goods not exceeding the transportation 
charges applicable to shipment from original destination unless the returned goods are free from 
defect and conform to specifications. Be sure to review the instruction booklet. Returned goods 
which are found by ATI to be free from defect and to conform to specifications shall be held for 
Purchaser’s shipping instructions, which instructions Purchaser shall furnish promptly upon 
request. 
 

ATI’s liability shall in no event extend beyond replacement, repair or refund of the 
purchase price and ATI shall not be liable under any circumstances for special, 
contingent or consequential damages, nor for loss, damages, or expenses directly or 
indirectly arising from the use of the goods, including without limitation, warehousing, 
labor, handling and service charges, die, equipment, or machine breakage, nor for costs, 
lost profits or loss of good will. The use of substitute, non-ATI parts and/or filters, in any 

Summary of Contents for AQUATRAP AT100S

Page 1: ...S These instructions must be carefully followed in order to operate the unit safely and correctly If there are any questions regarding the use of the unit please contact Abatement Technologies immediately at 800 634 9091 U S or 905 871 4720 Canada Abatement Technologies strongly urges users of commercial dehumidification units and related accessories to follow the most recent guidelines and or sta...

Page 2: ...emperature and or humidity drops a point will be reached where the surface temperature of the evaporator will be below freezing and the water will accumulate as frost on the evaporator surface Periodic defrosting will be required to melt the frost and to direct the water run off to the pump As to when defrosting takes place this is automatically determined and controlled by the unit The AT100S can...

Page 3: ...at prevents simultaneous start up of multiple units after a power outage and subsequent re energization If the unit was in operation before a power outage it will be re started automatically but randomly within 10 seconds when power resumes It is recommended that a Ground Fault Current Interrupt GFCI device be used in the electrical supply circuit A GFCI is an electrical safety device that will tr...

Page 4: ...on or recovery from a thermal overload over heating condition If all covers are not in place the intended protection from the motorized impeller will not be present keep clear of the motorized impeller to reduce the risk of injury WARNING To reduce risk of fire or electrical shock do not use the AT100S with any solid state speed control device CAUTION For general dehumidification use only Do not u...

Page 5: ...Hours Indicates the number of hours that the unit has been operating since it was last reset to zero To reset Job Hours to zero depress the ENTER button Total Hours Indicates the number of hours that the unit has been operating since it was new Language Setting Each press of the ENTER button cycles through the following languages on the LCD ENGLISH SPANISH FRENCH Press MENU to confirm the choice o...

Page 6: ...n remove the entire filter As long as the unit has not been tampered with and all panels are in place the unit has been designed to allow the filter to be changed without exposing the operator to mechanical or electrical hazards The original equipment high efficiency pleated air filter is rated MERV 8 and has been specifically designed to allow the unit to remain clean internally and perform to pu...

Page 7: ...sed well With the Heat Exchanger removed full access is available to clean the fins of the aluminum evaporator and condenser coils The dirtiest surfaces to be cleaned will be on the air entering sides Vacuuming with a brush should be effective at removing the debris if not contact qualified service personnel if more aggressive cleaning is required There is also full access to clean the Drain Pan D...

Page 8: ...residual water corrosive environment or other conditions beyond the control of ATI 6 Reimbursement for warrantable replacement parts not supplied by ATI 7 Shipping damage or damage as a result of abuse in transporting the unit ATI does not warrant that the goods sold are merchantable or fit for any particular purpose ATI makes no warranties other than as stated in this paragraph All other warranti...

Page 9: ...sistance contact Abatement Technologies Customer Service Department at 800 634 9091 U S or 905 871 4720 Canada AT100S SPECIFICATIONS AHAM Rating 80o 60 RH 100 Pts Day Dimensions 19 L x 18 3 W x 38 8 H Dehumidifier Type Low Grain Refrigerant LGR Water Removal at 80o F 20 RH Yes Weight 125 Pounds Shipping Weight 145 Pounds Cabinet Material Stainless Steel Filter MERV 8 Drain Hose Length 35 Feet Cord...

Page 10: ...d be within nameplate limits Compressor windings open Contact qualified service personnel Compressor Will Not Run Seized compressor Contact qualified service personnel Shorted or incorrect wiring Contact qualified service personnel Shorted capacitor Contact qualified service personnel Compressor short cycling See Compressor Short Cycles Fuse or breaker setting too low Check nameplate fuse size Bro...