V8000WD MK-2
8 Troubleshooting
F
au
lt
Cause
Remedy
‡ Motor does
not
start
> Fuse in mains plug has
blown
> Overload protection switch
has tripped
Reset the fuse.
Switch off the vacuum
cleaner and allow it to cool
for approx. 5 minutes. If it
cannot be started again,
contact AbatementTechnologies'
Technical Support.
‡ Motor does not run
> Power tool is defective or
not connected properly.
Check that the power tool
works or that the plug is
inserted correctly
.
‡
No suction power during > Tank is full (floater closes t Switch off the cleaner. Empty
wet cleaning.
suction opening). the tank.
Voltage fluctuations > Impedence of power supply Connect the cleaner to
is too high.
another socket closer to the
fuse box. Voltage fluctuations
over 7% should not occur if the
impedence at the transfer point is
plus or minus 0.15 ohms.
‡
8
8