Plumbing feeds - Floor fed
(Dimensions shown in mm)
Where wall entry is not possible, floor fed connections may also be made.
Hot & Cold -
Feeds should be fed in 22mm. Feeds should terminate with
full bore isolating
valves.
Elbow isolation valves may be used to improve plumbing routing where possible.
Isolation valves must be located so that they are easily accessible.
Waste
- 40mm Waste outlet @ 3ltr/sec. Waste pipe highest point
should not exceed 120mm
from the floor.
Side Wall Pre-install Plumbing
7
Left hand bath floor fed
plumbing locations
shown.
Note
: for right handed
bath plumbing will be
mirrored to opposite
side.
It is preferred that
plumbing feeds will
terminate anywhere
along the midpoint of the
green area outlined.
When the bath is fitted at
more that 100mm from
the wall, floor feed
centres should be 50mm
from the wall.
Pipework must not enter
the room in the location
shown in
orange
, as
doing so will hinder
installation.
Figure 5.0
Aries 2000 Installation Manual v1.0