16
PMC423* Port Serial, Front/Rear I/O
Publication No. RX-URMH 006 Rev. E.0
1.5.1
RS485 Support (SW2-SW12)
These switches are used when running a port in RS485 signaling mode. When
running RS485 (half duplex), the three switches associated with the port should be
Closed
. In all other signaling modes, the switches should be
Open
(see table below
for port/switch position assignments).
NOTE
The use of RS485 requires use of the correct software interface. Consult the driver manual for the operating
system used for details.
As shipped from factory, all switches are in the Open state.
Table 1-2 RS485 Support Switches (SW2-SW12)
Port
1
SW1:1
SW2:1
SW9:1
2
SW1:2
SW2:2
SW9:2
3
SW1:3
SW2:3
SW9:3
4
SW1:4
SW2:4
SW9:4
5
SW3:1
SW4:1
SW10:1
6
SW3:2
SW4:2
SW10:2
7
SW3:3
SW4:3
SW10:3
8
SW3:4
SW4:4
SW10:4
9
SW5:1
SW6:1
SW11:1
10
SW5:2
SW6:2
SW11:2
11
SW5:3
SW6:3
SW11:3
12
SW5:4
SW6:4
SW11:4
13
SW7:1
SW8:1
SW12:1
14
SW7:2
SW8:2
SW12:2
15
SW7:3
SW8:3
SW12:3
16
SW7:4
SW8:4
SW12:4
Where SW3:4 means Switch pack 4, switch 4, etc.
NOTE
The above applies to the Rev. D and later revisions of the board. For earlier revisions, please e-mail:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com