abaco systems PMC423 Hardware Reference Manual Download Page 15

 

14

  PMC423* Port Serial, Front/Rear I/O  

 

Publication No. RX-URMH 006 Rev. E.0 

1.5  I/O Signal Pinouts 

Each serial port has two control signals: 

 

TX - Transmitted Data 

 

RX - Received Data 

To support differential signaling standards (e.g., RS422), each signal has a positive 
and negative line. When using a single ended standard (e.g., RS232), use the negative 
version. 

 

All I/O signals are available both at the front panel connector and on the J4 
“backplane” connector. The following table details all connections. 

Table 1-1 I/O Signal Pinouts PMC423

 

Port 

Signal 

Front Panel Pin 

J4 Pin 

Positive  Negative  Positive  Negative 

RX 

TX 

RX 

TX 

RX 

11 

10 

10 

TX 

13 

12 

12 

11 

RX 

15 

14 

14 

13 

TX 

17 

16 

16 

15 

RX 

19 

18 

18 

17 

TX 

21 

20 

20 

19 

RX 

23 

22 

22 

21 

TX 

25 

24 

24 

23 

RX 

28 

26 

26 

25 

TX 

30 

29 

28 

27 

RX 

32 

31 

30 

29 

TX 

34 

33 

32 

31 

RX 

36 

35 

34 

33 

TX 

38 

37 

36 

35 

10 

RX 

40 

39 

38 

37 

TX 

42 

41 

40 

39 

11 

RX 

45 

44 

42 

41 

TX 

47 

46 

44 

43 

12 

RX 

49 

48 

46 

45 

TX 

51 

50 

48 

47 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PMC423

Page 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective o...

Page 2: ...O THE PMC423 IS DESIGNED TO MEET THE EUROPEAN UNION EU RESTRICTIONS OF HAZARDOUS SUBSTANCE ROHS DIRECTIVE 2002 95 EC CURRENT REVISION Publication No RX URMH 006 Rev E 0 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...Returns Abaco Systems is registered with an approved Producer Compliance Scheme PCS and subject to suitable contractual arrangements being in place will ensure WEEE is processed in accordance with the requirements of the WEEE Directive Abaco Systems will evaluate requests to take back products purchased by our customers before August 13 2005 on a case by case basis A WEEE management fee may apply ...

Page 4: ...The prefix 0x shows a hexadecimal number following the C programming language convention Thus One dozen 12D 0x0C 1100b The multipliers k M and G have their conventional scientific and engineering meanings of x103 x106 and x109 respectively and can be used to define a transfer rate The only exception to this is in the description of the size of memory areas when K M and G mean x210 x220 and x230 re...

Page 5: ...ance contact details on the Embedded Support page LINK https www abaco com embedded support Abaco will log your query in the Technical Support database and allocate it a unique Case number for use in any future correspondence Alternatively you may also contact Abaco s Technical Support at the website below LINK support abaco com Returns If you need to return a product there is a Return Materials A...

Page 6: ...Features The PMC423 is a powerful and flexible method to integrate serial data channels to a PCI system Features include Sixteen independent serial channels Programmable baud rate from 100 bits second to 921 6Kbits s with default Crystal at 14 7456 MHz UART register sets compatible with 16C550 64 Byte First in First out FIFO per channel Full PCI compatibility 32 bit 33 and 66 MHz PCI capable Signa...

Page 7: ...ve Atmosphere Do not operate the system in the presence of flammable gases or fumes Operation of any electrical system in such an environment constitutes a definite safety hazard Keep Away from Live Circuits Operating personnel must not remove product covers Component replacement and internal adjustments must be made by qualified maintenance personnel Do not replace components with power cable con...

Page 8: ...utions 10 1 2 Unpacking Procedures 10 1 3 Installation 11 1 4 Front Panel Connectors and Indicators 12 1 5 I O Signal Pinouts 14 1 5 1 RS485 Support SW2 SW12 16 2 Theory of Operation 18 2 1 PMC423 Block Diagram 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 9: ...r I O Publication No RX URMH 006 Rev E 0 List of Tables Table 1 1 I O Signal Pinouts PMC423 14 Table 1 2 RS485 Support Switches SW2 SW12 16 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 10: ...ure 1 1 Installation of PMC Module 11 Figure 1 2 Front Panel Connectors and Indicator 12 Figure 1 3 PIM422 13 Figure 1 4 Default Switch Settings 17 Figure 2 1 PMC423 Block Diagram 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 11: ...iguring etc it is suggested that conductive material be inserted under the board to provide a conductive shunt Unused boards should be stored in the same protective boxes in which they were shipped 1 2 Unpacking Procedures Any precautions found in the shipping container should be observed All items should be carefully unpacked and thoroughly inspected for damage that might have occurred during shi...

Page 12: ...g connectors on the host s printed circuit board 5 Make sure the PMC module is seated properly into the common mezzanine card CMC connectors on the host 6 Use screws to fasten PMC to the host CMC 7 Remove the four screws from the bottom of the stand offs of the PMC 8 Lineup the J1 and J2 connectors on the host CMC to the J1 and J2 connectors on the PMC 9 Ensure all connectors are properly aligned ...

Page 13: ...onnectors and Indicators The front panel connector is a high density small computer system interface SCSI female connector AMP part number AMP 796055 1 Figure 1 2 Front Panel Connectors and Indicator Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 14: ...Publication No RX URMH 006 Rev E 0 Handling and Installation 13 Figure 1 3 PIM422 TOP BOTTOM Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 15: ...lane connector The following table details all connections Table 1 1 I O Signal Pinouts PMC423 Port Signal Front Panel Pin J4 Pin Positive Negative Positive Negative 1 RX 2 1 2 1 TX 4 3 4 3 2 RX 6 5 6 5 TX 8 7 8 7 3 RX 11 10 10 9 TX 13 12 12 11 4 RX 15 14 14 13 TX 17 16 16 15 5 RX 19 18 18 17 TX 21 20 20 19 6 RX 23 22 22 21 TX 25 24 24 23 7 RX 28 26 26 25 TX 30 29 28 27 8 RX 32 31 30 29 TX 34 33 3...

Page 16: ...Positive Negative 13 RX 53 52 50 49 TX 55 54 52 51 14 RX 57 56 54 53 TX 59 58 56 55 15 RX 62 60 58 57 TX 64 63 60 59 16 RX 66 65 62 61 TX 68 67 64 63 NOTE Ground is available on the front panel connector on pins 9 27 43 and 61 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 17: ...ls As shipped from factory all switches are in the Open state Table 1 2 RS485 Support Switches SW2 SW12 Port 1 SW1 1 SW2 1 SW9 1 2 SW1 2 SW2 2 SW9 2 3 SW1 3 SW2 3 SW9 3 4 SW1 4 SW2 4 SW9 4 5 SW3 1 SW4 1 SW10 1 6 SW3 2 SW4 2 SW10 2 7 SW3 3 SW4 3 SW10 3 8 SW3 4 SW4 4 SW10 4 9 SW5 1 SW6 1 SW11 1 10 SW5 2 SW6 2 SW11 2 11 SW5 3 SW6 3 SW11 3 12 SW5 4 SW6 4 SW11 4 13 SW7 1 SW8 1 SW12 1 14 SW7 2 SW8 2 SW1...

Page 18: ...Publication No RX URMH 006 Rev E 0 Handling and Installation 17 Figure 1 4 Default Switch Settings Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 19: ...or the serial communication RS232 RS422 etc is configured via the software The card generates the necessary voltage for the serial signaling onboard using the 5 V supply This allows the PMC423 to operate from the 3 3 V and 5 V supply only There are two eight port serial devices that are after the PCI to PCI bridge for a total of sixteen ports Due to the density of the serial ports the hardware han...

Page 20: ...cter transferred and control operations The Octal UART utilized on the PMC423 supports 32 bit transfers allowing four characters to be transferred in a single bus operation Reducing programmed I O operations is critical to achieving good performance in PCI systems While the extended transfer options offer an opportunity to maximize performance in many cases the first and sometimes only criteria ar...

Page 21: ...ITH NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OTHER LIABILITY ARISING FROM RELIANCE ON ANY INFORMATION CONTAINED HEREIN IS EXPRESSLY DISCLAIMED Abaco Systems Information Centers Americas 1 866 652 2226 866 OK ABACO Europe Middle East and Africa 44 0 1327 359444 Ad...

Page 22: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: