V. TECHNICAL PROBLEMS & SOLUTIONS:
No.
Cause
Solution
Image
1
Loose suction
cups
Suction cups
have dust or
damaged
Clean the suction
cups or replace
with a new one.
2 The vacuum
pressure
gauge
indication is
not between
-70 and -80
kPa
Damaged
pipes, air
leakage in
tubes and
valves
Inspect the
piping by using
diluted neutral
soapy water to
find suspected
leaks. Then
repair or replace
the tube or
device.
Pneumatic
cylinder slips
while lifting
and adjusting
the angle.
Inspect the
piping by using
diluted neutral
soapy water to
find suspected
leaks. Then
repair or replace
the tube or
device.
- Damaged
pipes, air
leaks in pipes
and valves
- Air pressure
is less than 6
bar.
3
Technical
problem
4
Difficult to
rotate the
stone slab 90
o
(the loading
is within the
W.L.L)
The rotary
joint is rusted
Clean the rust
oil, grease into
the joint.
5
The handle is
difficult to
pull out
Dust and/ or
rust
Clean and
lubricate
Summary of Contents for SVL100
Page 2: ......
Page 3: ...APPLICABLE MODEL of this STONE VACUUM LIFTER SVL100 OPERATION MANUAL ...
Page 6: ...1 ...
Page 7: ...Trolley stand Suction cup Vacuum tank Pneumatic cylinders Frame Control panel 2 ...
Page 9: ...4 2 Spare part list Overall ...
Page 12: ...3 Spare part list Trolley stand 7 ...
Page 14: ...4 Spare part list Suction cup left 9 ...
Page 16: ...5 Spare part list Suction cup right 11 ...
Page 24: ...19 Figure 1 3 4 CONTROL SYSTEM OVERVIEW ...
Page 31: ...26 Step 7 Place the stone slab at the desired postion figure 7 1 Figure 7 1 ...
Page 32: ...Figure 8 1 Figure 8 2 Figure 8 3 27 Stopper pin ...
Page 41: ......
Page 42: ......
Page 43: ...All Right Reserved J19 ...
Page 44: ......