background image

Solares

TM

 Smart Spa Installation Manual 

CD0037 

-13- 

1121 

 

Tub Drain Preparation and Connection 

Typical Drain Connections: 

 

PVC hard plumbed connection.

 

 

Rubber flexible coupler connection.

 

 

Drain terminates into floor sink.

 

Note: Drain line must not be located more than a 
¼” off the floor for proper drainage. 

 

PVC Hard Plumbed Example 

 

 

Summary of Contents for Solares Smart Spa

Page 1: ...rt Spa Specifications Installation Manual Part Number 990130 With Rapid FillTM Option Without Rapid FillTM Option 450 Main Street Somerset WI 54025 Phone 715 247 5625 Fax 715 247 3424 Website http www apollobath com ...

Page 2: ...omponents and finish of the system If the unit is installed during construction it is the installer s responsibility to ensure the system is adequately protected from such contaminants Flush Hot and Cold water lines prior to connecting to bathing system Debris left in the water lines can cause valve failure Allow bathing system to reach room temperature before plugging it in Electric components ca...

Page 3: ...h built in backflow prevention However due to different plumbing codes it is advisable that you ask your installer whether there is a need to install additional backflow prevention valves such as RPZ valves on any new construction NOTE Lock Out or Tag Out electrical circuit for bathing system BEFORE installation Electrical Protection Class 1 Type B applied part Bathing system installation must com...

Page 4: ...it breaker not supplied Tub Fill Electrically controlled ASSE 1016 certified Thermoscopic mixing valve Shower Handheld with 84 in 213 4 cm ANSI A112 18 1 hose Tub Entry Door with 25 4 in 64 5 cm opening where residents are transferred into tub Gasket D shaped ASTM D2000 solid EPDM extrusion Whirlpool Pump Motor 0 75 HP 110 120VAC 60 Hz 7 A 92 5 GPM max flowrate Whirlpool Jets 5 aerated whirlpool j...

Page 5: ...resTM Smart Spa Installation Manual CD0037 5 1121 Symbol Definitions Acceptable storage temperature range Acceptable storage humidity range Consult accompanying documents Protective Earth AC and DC Current ...

Page 6: ...perating normally Portable RF communications equipment can affect medical electrical equipment Such equipment should be used no closer than 12 from the tub CAUTION Bathing room characteristics including room dimensions door sizes and floor drain placement must comply with all applicable building and health codes NOTE Clearance of 18 in 46 cm or more is recommended for ease of use and serviceabilit...

Page 7: ...SolaresTM Smart Spa Installation Manual CD0037 7 1121 Bathing System Dimensions ...

Page 8: ...I breaker Most codes require electrical to be located above the water supply Minimum required water pressure is 30 PSI 2 1 Bar for both hot and cold water supply Images below show the recommended locations for the electrical and water supply Electrical and water supply can be located anywhere within the enclosed area Bathing System WITH Rapid FillTM Option ...

Page 9: ...SolaresTM Smart Spa Installation Manual CD0037 9 1121 Electrical Plumbing Service Installation Cont Bathing System WITHOUT Rapid FillTM Option ...

Page 10: ...of the frame Use an 11 16 wrench to adjust the leveling feet Turn the nut clockwise to drop the foot down raise the tub and counterclockwise to lift the foot up lower the tub When adjusting the level at the front of the tub only adjust the foot on the side where the floor is lower The frame on the higher side should always be 3 3 in 8 4 cm off the ground See images below ...

Page 11: ...ng contact If the rear wheels of the carrier fall into a valley such as a floor drain when docking it may be necessary to lower the frame below the nominal 3 3 to ensure a smooth transfer Once the front of the tub is level finish leveling the tub by adjusting either or both of the feet at the back of the tub For best results tilt the tub to its highest position and place a level along the rails in...

Page 12: ...ilt and hold the up arrow until the tub stops raising It s worth noting that leveling is for drainage purposes If the tub cannot be perfectly leveled due to an extreme slope in the floor it is acceptable to just get it as close to level as possible Make sure all leveling feet make firm contact with the ground ...

Page 13: ...Drain Preparation and Connection Typical Drain Connections PVC hard plumbed connection Rubber flexible coupler connection Drain terminates into floor sink Note Drain line must not be located more than a off the floor for proper drainage PVC Hard Plumbed Example ...

Page 14: ...SolaresTM Smart Spa Installation Manual CD0037 14 1121 Rubber Flexible Coupler Example ...

Page 15: ...SolaresTM Smart Spa Installation Manual CD0037 15 1121 Floor Sink Example ...

Page 16: ...per bulb See Side Panel Trim Removal for detailed instructions Slide the UV bulbs into the Remedy Chambers behind the tub It s important to keep them parallel with the inside of the chamber to prevent damaging the quartz tube inside Connect the cables coming off the rear most electrical box to the bulbs Thread the UV Bulb Retainer Plug located on the cable into the end of the chamber Fitting shoul...

Page 17: ...wn and out to remove from tub 6 When ready to reinstall start by tucking front of trim into front edge of tub 7 Slide trim up until top edge of trim is recessed behind tub shell 8 Align rear slots of frame with threaded inserts in the back of the frame as seen in Detail A and loosely install the screws 9 Lift the front edge of the frame up until the slots line up with the holes located towards the...