Overview
1–4
LED Indicators
Seven LEDs provide the following indications.
Indicator
Condition
Indicates:
Green
Normal operating state
Flashing Green
Initialization and/or incorrect (unconfigured)
configuration
Module
Red
Processor fault (nonrecoverable)
Module
Flashing Red
Minor fault (recoverable). Occurs when down-
loading firmware.
Off
No power applied to Reader
Green
Normal DeviceNet operating state
Flashing Green
Communication link established, but not data
transfer.
Netw r
Red
Communication fault
Network
Flashing Red
One or more DeviceNet devices are not re-
sponding. Reader may not be able to perform
all configured functions.
Off
DeviceNet communications not established
La er
Yellow
Scan beam on
Laser On
Off
Scan beam off
Yellow
Scanning and decoding bar code symbol
On Symbol
Flashing
Bar code symbol read at less than 100% rate
On Symbol
Off
Not scanning bar code symbol
Yellow
Package detected
Trigger / Read
Green
Valid read
Trigger / Read
Off
No trigger or no valid bar code symbol read
I/ 1
Yellow
Input/Output module 1 active
I/O 1
Off
Input/Output module 1 not active
I/ 2
Yellow
Input/Output module 2 active
I/O 2
Off
Input/Output module 2 not active
Wiring Base Connector
The 24-pin connector on the bottom of the Reader plugs into the
socket on the wiring base. No other connections to the Reader are
required.
Operating Environment
The Reader operates under a variety of conditions.
•
Cast aluminum enclosure meets NEMA Type 4 requirements
when used with the wiring base.
•
Operates in environments from 32 to 122
F (0 to 50
C).
•
Mounts at any angle.
See Appendix A for a complete list of Reader specifications.