The following table describes the labels in this screen.
Label
Description
Maximum Power
Available
Display the maximum power available.
System Power Limit
Set the system power limit.
Actual Power
Consumption
Display the actual power consumption.
Main Supply Voltage
Display the main supply voltage.
Firmware Version
Display the firmware version.
Pork Knockoff
Disabled
Mark the blank to enable “Pork Knock off Disabled” function.
AC Disconnect
Mark the blank to enable “
AC Disconnect
” function.
Capacitive Detection
Mark the blank to enable “
Capacitive Detection
” function
Start
Mark the blank to enable “
P.O.E.
” function.
Apply
Click “
Apply
” to set the configurations.
P.S.E. port control setting interface
The following table describes the labels in this screen.
Label
Description
Port
Port number.
Enable state
Mark the blank to enable P.O.E. function for specific ports
Power Limit From
Classification
Set the “
Power Limit From Classification
” function for each
P.O.E. ports
Legacy
The legacy detection is to identify the PD devices that did not
follow the IEEE 802.3af standard their unique electrical signatures
in order for the PoE switch can provide the power to those PD
devices
Priority
Set port priority for the P.O.E. power management. 1 = C (critical),
2 = H (High), 3 = L (Low)
Power Limit
Set the power limit value. The maximum value must less 15400
Mode
Display the PD current operation mode status