![AAT KaDe KDH-KZ2000-IP-M Installation Manual Download Page 4](http://html1.mh-extra.com/html/aat/kade-kdh-kz2000-ip-m/kade-kdh-kz2000-ip-m_installation-manual_450322004.webp)
Integrated Access Controller –
Installation manual
4
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
Parameter or function name
Parameter value
or function description
Buffer capacity
-
Card buffer
20 000 (2 000 in standalone mode)
-
Event buffer
-
Alarm buffer
50 000
20 000
Electrical parameter
-
Supply power
12 VDC
-
Current load
< 110 mA
-
anti
-
static capability
:
YES
Environment parameter
-
Environment
For indoor installation only
-
Working Temperature
From+2
°
C to 55
°
C
-
Relative Humidity
0%
-
95%
-
Size (L x W X H)
122 x 77 x 39 mm
Communication ports
For connection with KaDe Premium Plus
-
TCP
For additional module connection
-
RS485 (for future used)
Readers and Cards
-
Integrated reader
For UNIQUE card, read range 5
-
10 cm (U)
For MIFARE card, red range
2
–
5
cm (M)
-
External (for two way control)
26 (U)/34(M) bit Wiegand output format
-
Card format
ISO UNIQUE (125 kHz)
MIFARE (14443A) (13,56 MHz)
-
External reader keypad PIN format
4
-
bits, without buffering
Inputs
-
Door contact input
NO / NC (NO
-
default)
-
Exit button input
NO / NC (NO
-
default)
-
PIR input
NO / NC (NO
-
default)
Relay output
-
Strike (lock) control
Relay DC 12V 1A (NO / C / NC)
-
Alarm control
Relay DC 12V 1A (NO / C / NC)
-
Bell control
NO/NC
Access level parameter
-
Access level
200
-
Schedule
184
-
Holiday
32
Identification mode
Card, Card + PIN, PIN , Card or PIN
Alarm relive
Automatic, manually by operator or by card
2. KDH
-
KZ2000
-
IP
-
U_M controller technical data