Integrated Access Controller –
Installation manual
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
All rights reserved.
15
Programming the controller in network mode
Controller KDH
-
KZ2000
-
IP
-
U_M can operate in stand
-
alone mode or net-
work mode under the supervisory software installed on computer.
It is also possible operation of the controller in the "off
-
line" after programming
with the supervisory software when the controller is connected through an IP
port.
Supervisory program on PC gives a much more powerful programming and mon-
itoring system based on controllers KDH
-
KZ2000
-
IP
-
U_M. A detailed description
of controller programming in network mode refer to the instructions for the
KaDe Premium Plus II
software
and the help files dynamically displayed on
the operator panel.
General guidelines for the installation of the controller
•
Before installing the controller should be familiar with this manual.
•
Installation of the controller can be performed only by qualified personnel
with the appropriate certified to install and service this type of equipment.
•
The controller must be installed within a protected space at a temperature
of above + 2 ° C and normal humidity.
•
Controllers in the system should be located so that the minimum distance
from cables and high
-
voltage devices and other devices that generate elec-
trical noise was 2 m. The minimum distance from telephone lines should be
1 m, and from 8 m transmitting devices.
•
As the housing of the controller is equipped with a tamper sensor so care
must be taken to the surface for mounting the controller housing it was
hard and smooth.
•
The controller should be powered from a linear power supply with backup
battery with parameters. 12 VDC, 1A. This takes into account the possible
supply of an electric lock with the same power supply. In this case the at
the lock terminals should be installed diode 1N4004 in the reverse direction.
•
Wiring and performing any work on the internal components of the control-
ler while power is categorically prohibited. This can lead to damage.
•
Before connecting the controller to the power supply must perform all the
necessary connections in accordance with the instructions.
•
The connection to the computer is to be implemented using the IP port.
•
Each controller must be set to a different IP address.
NOTES:
Tamper and recover administrator and communication password
(for location look at diagram on page 8):
Keeping pressing the button (with small spring), device will under tamper status.
To clear administrator password by pressing the button for three times, and
administrator password return to default 000000 and clear communication
password.