background image

TA7104i Hardware Installation 

 

© 2014 Aastra Sweden | 154_1531 ANF 901| A | 2014-05-15 

19 

 

  Using a network packet sniffer (e.g., Wireshark) to examine the DHCP messages 

exchanged between the TA7104i and your DHCP server while the TA7104i boots up. 

  The TA7104i should be already running. If not, power it on by connecting the other end of 

the power adaptor to an electrical earthed socket-outlet. The electrical outlet must be 
installed near the TA7104i so that it is easily accessible. 

 

Note: 

If the 

Power 

LED is always blinking and never turns on, this means that the TA7104i 

cannot find either an IPv4 DHCP server or an IPv6 address automatically. Check that you have 
a DHCP server properly configured on your network. If you do not have a DHCP server, go to 
the section Default Static IPv4 Address Configuration. 
You can now access the TA7104i web interface. Refer to the 

Software Configuration Guide

 for 

more details. 
 

Initial Provisioning Sequence

 

 
When starting the TA7104i for the first time, it needs to be configured before it can support calls. 
This process is known as 

provisioning

. This sequence assumes that you have installed the 

TA7104i hardware as per 

Hardware Installation

The TA7104i requests its configuration only on the first restart. You can change the 
configuration at will after the initial provisioning and the provisioning system can refresh the 
TA7104i configuration. 
 

 

Initial provisioning sequence:

 

 

1.  When the TA7104i starts, it broadcasts a message requesting DHCP services (if the unit is 

configured to start in DHCP mode). 

2.  The DHCP server responds with a set of IP addresses and network parameters, one of 

which is the TA7104i IP address. 

The following are some of the network parameters assigned via DHCP: 
 

  TA7104i IP address 

  Subnet Mask 

  Default Router IP address 

  DNS IP addresses 

  Configuration script server IP address and port number (optional) 

  SIP Servers IP address and port number 

 

The TA7104i request its configuration by using a configuration file. 

 

Default Static IPv4 Address Configuration

 

 
If there is no DHCP server in your network, then the IP address has to be configured statically. 
 

 

To start the TA7104i with a static IP address:

 

Summary of Contents for TA710i

Page 1: ...TA7104i Hardware Installation Guide...

Page 2: ...Recommendations 12 3 3 Required Mounting Tools and Equipment 13 3 4 Unpacking and Inspection 13 3 5 Location and Mounting Requirements 13 3 6 Hardware Installation 17 4 Powering on the TA7104i 18 4 1...

Page 3: ...tion may be subject to alteration modification or commercial use Aastra will not be liable for any damages arising from use of an illegal modified or altered publication Trademark Aastra is a register...

Page 4: ...guide consists of Hardware descriptions of the TA7104i device Hardware installation instructions Installation scenarios examples LED indications Cabling and pin out data Note There are many flavours...

Page 5: ...rty software modules used in the TA7104i along with any copyright and license information Be sure to read any readme files technical bulletins or additional release notes for important information 1 4...

Page 6: ...ventions you will encounter in this manual Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury and or damage to the equipment or property No...

Page 7: ...TA7104i Hardware Installation 2014 Aastra Sweden 154_1531 ANF 901 A 2014 04 15 6 For more information on and a list of RFCs and Internet Drafts refer to the IETF web site at http www ietf org...

Page 8: ...ting standard analog lines The TA7104i offers two Ethernet connectors switches enabling to establish two connections between conventional analog telephones or Group 3 fax machines and either a WAN a L...

Page 9: ...4i Front Panel Indicators Table 2 describes the connectors on the front panel of the TA7104i Table 2 TA7104i Front LEDs LED Descriptio n 1 Ready When lit the TA7104i is ready to initiate or receive a...

Page 10: ...Default switch Resets configuration parameters of the TA7104i to default known values It can be used to reconfigure the unit Warning Read Section RESET DEFAULT Button on page 18 before attempting to r...

Page 11: ...eeded to configure the TA7104i see section Network Information Installation Checklist The installation checklist lists the tasks for installing the TA7104i Print a copy of this checklist and mark the...

Page 12: ...Update the site log to reflect the following Configuration changes Maintenance schedules requirements and procedures performed Comments notes and problems Software changes and updates to firmware Net...

Page 13: ...ON Use caution when working near these connectors to avoid electric shock When detaching cables detach the end away from the TA7104i first General Safety Practices Follow these guidelines to ensure pe...

Page 14: ...e contains the following items 1 x TA7104i unit 1 x power supply for the country in which you are using the TA7104i 1 x BumponTM kit for desktop use 1 x Printed Flyer You may also need additional 10 1...

Page 15: ...f the TA7104i The airflow is not restricted around the TA7104i or through the vents of the unit The unit requires a minimum of 25 mm 1 in clearance The operating temperature is between 0 C and 40 C Th...

Page 16: ...the TA7104i These will improve airflow under the unit 4 Position the TA7104i against the wall or plywood as illustrated in Figure 4 Figure 4 Bottom View Wall Mounting Screw Holes Rear Screw holes Fro...

Page 17: ...that might be harmful to the unit If this occurs allow the unit to acclimatize for an hour before powering it on Cleaning To clean the TA7104i wipe with a soft dry cloth Do not use volatile liquids s...

Page 18: ...terface with a conventional telephone or fax machine Connections to FXS ports of third party devices such as a PBX Key System could damage the TA7104i Connect a 10 100 BaseT Ethernet RJ 45 cable into...

Page 19: ...address in the same subnet via a DHCP server or PPP peer you will not be able to contact the unit via the WAN You must be careful that a dynamic IP address does not overlap a static IP subnet that is...

Page 20: ...st time it needs to be configured before it can support calls This process is known as provisioning This sequence assumes that you have installed the TA7104i hardware as per Hardware Installation The...

Page 21: ...or more details IPv6 Link Local Address Configuration If there is no DHCPv6 server or IPv6 router in your network you can use the link local address to contact the unit Note that the TA7104i IPv6 inte...

Page 22: ...you with relevant information To access vocal unit information 1 Take one of the telephones connected to the TA7104i 2 Dial one of the digits sequence on the keypad Table 4 Vocal Unit Information Digi...

Page 23: ...coveryPending Triggered when the RESET DEFAULT button is pressed at start time or for at least 7 seconds All LEDs blinking 1Hz 50 duty DefaultSettingsPendin g Triggered when the RESET DEFAULT button i...

Page 24: ...Bank Triggered when the unit is booting on the recovery bank and no update is pending Power LED blinking 0 25Hz 75 duty Automatic network configuration in progress Waiting for DHCP IPv4 or IPv6 answer...

Page 25: ...g variable rate No network traffic Steady ON LED Type Condition Behaviour In Use Lines Idle and Unlocked Steady OFF Lines InUse and Unlocked Steady ON Shutting Down Steady yellow Locked Blinking yello...

Page 26: ...seconds Sets the TA7104i in Partial Reset Mode Sets some of the TA7012i configuration to pre determined values All LEDs blinking 1Hz 50 duty 12 to 16 seconds Restarts the TA7104i in Factory Reset Del...

Page 27: ...nmpPort values to their default values 3 WEB service Resets the serverPort to its default value To trigger the Partial Reset 1 Insert a small unbent paper clip into the RESET DEFAULT hole located at t...

Page 28: ...This procedure resets all variables in the MIB modules to their default value When the TA7104i has finished its provisioning sequence it is ready to be used with a DHCP provided IP address and MIB par...

Page 29: ...TA7104i Hardware Installation 2014 Aastra Sweden 154_1531 ANF 901 A 2014 05 15 28 Unit Manager Network The UMN offers the following Auto discovery Group provisioning SNMP access and remote management...

Page 30: ...s and Interruptions Note The standards compliance of the TA7104i are printed on a sticker located on the bottom of the unit 5 1 Disclaimers The following are the disclaimers related to the TA7104i Fed...

Page 31: ...t and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note Any chang...

Page 32: ...inden sich in einer Situation die zu einer K rperverletzung f hren k nnte Bevor Sie mit der Arbeit an irgendeinem Ger t beginnen seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren u...

Page 33: ...ductors all current carrying conductors TN Power Warning Warning The device is designed to work with TN power systems Product Disposal Warning Warning Ultimate disposal of this product should be handl...

Page 34: ...ations To insure general safety follow these guidelines Do not open or disassemble this product Do not get this product wet or pour liquids into it Do not perform any action that creates a potential h...

Page 35: ...with a minimum of 26 AWG wire size It is possible to use either a crossover or straight Ethernet cable to connect in the Ethernet connectors These connectors perform automatic MDI MDIX detection mean...

Page 36: ...ue stripe 6 Receive Orange with white stripe or solid orange Green with white stripe or solid green 7 N A White with brown stripe or solid brown White with brown stripe or solid brown 8 N A Brown with...

Page 37: ...8 not connected Crossover Cable A RJ 45 crossover cable is used when only two systems are to be connected to each other peer to peer at the Ethernet Cards by crossing over reversing their respective p...

Page 38: ...ends of the cable Each wire pair must be attached to the RJ 11 connectors in a specific orientation The following figure illustrates how the pins on the RJ 11 connector are numbered Be sure to hold th...

Page 39: ...or the being reserved for special purposes Dynamic Host Configuration Protocol DHCP TCP IP protocol that enables PCs and workstations to get temporary or permanent IP addresses out of a pool from cen...

Page 40: ...systems Typically defines how to implement a group of services in one or two layers of the OSI reference model Protocols can describe low level details of machine to machine interfaces or high level e...

Page 41: ...age or protocol of the Internet It can also be used as a communications protocol in a private network either an intranet or an extranet Voice Over IP VoIP The technology used to transmit voice convers...

Page 42: ...Force IP Internet Protocol LAN Local Area Network ma milliampere MAC Media Access Control MDI Media Dependent Interface MDIX Media Dependent Interface Crossover PBX Private Branch eXchange PSTN Publi...

Page 43: ...m or translated into another language without the prior written consent of Aastra Technologies Limited Concord Ontario Canada NOTICE The information in this document is subject to change without notic...