Connections of control inputs and relay outputs
Freely connectable relay
The two freely connectable relay contacts can be used to control external devices
or equipment such as heating, alarm or outdoor lighting systems (possibly via ex-
ternal relay for 230 VAC).
There are no special requirements for the cables.
Tab. 52
Relay operating data
Socket X2
Pin
Signal
Socket X4
Pin
Signal
1
–
1
–
2
–
2
–
3
I3-1
3
–
4
I4-1
4
–
5
I4-2
5
–
6
I3-2
6
–
7
–
7
–
8
–
8
–
IO port
Signal
Function
1
O1-1, O1-2
Floating contact, relay 1
2
O2-1, O2-2
Floating contact, relay 2
3
I3-1, I3-2
Control input 1
4
I4-1, I4-2
Control input 2
Parameter
Value
Number of changeover switches per relay
1
Insulation between the changeover
switches
0.5 kV
Type of contact
no (normally open, NO contact, make contact)
max. contact loading
24 VDC, 30 VAC, 1 A