Page 9 American Access Systems / Security Brands, Inc.
PROGRAMMING
A person desiring access to the program mode will enter the present MASTER CODE. If the master code is valid
the yellow LED will come on and the individual will be prompted with a QUICKBEEP to enter a 3 digit number
corresponding to a SUBMODE. There are 4 groups of SUBMODES. Group 100 is for PROGRAMMING CODES, group 200
is for DELETING CODES, group 300 is MISCELLANEOUS SETTINGS and GROUP 400 is PRINT FUNCTIONS. There are a total
of 26 different submodes to choose from. They are as follows:
GROUP 100 SUBMODES (PROGRAMMING CODES)
SUBMODE
DESCRIPTION
100
Program Access Cards (Block Format)
101
Program Managers Card(s) (Block Format)
102
Program Sleep Card(s) (Block Format)
103
Program Relay A Latch Card(s) (Block Format)
104
Program Relay B Latch Card(s) (Block Format)
105
Program Relay B Card(s) (Block Format)
106
Set System Facility Code (3 max.)
108
Change System Master Code
109
Change Quick Entry Master Code
110
Change Quick Delete Master Code
GROUP 200 SUBMODES (DELETING CODES)
SUBMODE
DESCRIPTION
200
Delete Cod Delete Card(s) (Block Format)
299
Clear APB status
GROUP 300 SUBMODES (MISCELLANEOUS)
SUBMODE
DESCRIPTION
300
Set Relay A Output Time (1/2 to 99 seconds)
301
Set Relay B Output Time (1/2 to 99 seconds)
302
Set Clock Time (Military Format)
GROUP 400 SUBMODES (PRINT FUNCTIONS)
SUBMODE
DESCRIPTION
400
Print Audit Trail (Entire Contents of History Buffer)
401
Print Out All Current Access Cards
402
Print Audit Trail on Specific Card
403
Set Printer Baud Rate
404
Red Printing on Invalid Cards (For AAS idp562 Citizen Printer Only)
405
Print Out Current Unit Configuration (Prints out Status of Split Relay,
APB, Current Baud Rate, All Manager’s and Second Relay Cards)
499
Clear Entire History Buffer