Page 19
Aarrow Signature Inset 5
SERVICE & MAINTENANCE
Please Note—This should be carried out when
the fire is cold and unlit.
Fig. 10. Positioning The Glass
Fig. 11. Tightening The Glass Clip
FIRE DOOR PRIMARY AIR INLET
Once a year a check is required to inspect the
primary air inlet assembly, located at the base of
the fire door.
•
Lift the door assembly from the stove body
and place on a level work bench, with the
rear face upper most.
•
Remove the 2 x no. fixings.
•
Working from the front, withdraw the oval
assembly from the door casting.
•
Clean the air slots within the door casting
and slider plate.
•
Place the oval assembly into the door oval
aperture and fix from the rear of the door.
See Fig 12
Fig. 12. Rear Of Oval / Slider Assembly
Slider
Rear Of Oval