Page 4

 

Symbols 

 

Symbols 

Function / Meaning 

Recommended Action 

 

Standby and on switch 

 

 

 

Battery installation guide 

 

 

 

Direct current 

 

 

SN 

Serial number 

 

 

 

Date of manufacture 

 

 

 

Type BF: Device, cuff and tubing are designed to provide 
special protection against electrical shocks. 

 

 

 

The indicator while measurement is in progress. It blinks 
while detecting the pulse. 

Measurement is in progress. Remain as still as 
possible. 

 

I

rregular 

H

eart

b

eat indicator. (I.H.B.) 

The indicator that detects irregular heartbeats or any 
excessive body movement during the measurement. 

 

 

 

Previous measurements stored in MEMORY. 

 

 

           

   Full Battery

The battery power indicator during measurement.   

 

 

  low Battery

The battery is low when it blinks.

 

 

Replace all batteries with new ones when the 
indicator blinks. 

Unstable blood pressure due to movement during the 
measurement. 

Try measurement again. 
Remain very still during the measurement. 

 

The systolic and diastolic values are within 10 mmHg of 
each other. 

The pressure value did not increase during inflation. 

 

The cuff is not fastened correctly. 

E

 

The pulse is not detected correctly. 

Fasten the cuff correctly, and try measurement 
again. 

SYS 

Systolic blood pressure in mmHg 

 

 

Summary of Contents for UB-511

Page 1: ...Wrist Digital Blood Pressure Monitor Model UB 511 WM PD4000888A...

Page 2: ...easurement 7 Measurements 8 Normal Measurements 8 Notes For Proper Measurement 9 Operation Mode 9 What Is An Irregular Heartbeat 10 Pressure Bar Indicator 10 WHO Classification Indicator 11 About Bloo...

Page 3: ...fants Environment for use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust shou...

Page 4: ...Page 3 Parts Identification...

Page 5: ...rtbeats or any excessive body movement during the measurement Previous measurements stored in MEMORY FullBattery The battery power indicator during measurement lowBattery The battery is low when it bl...

Page 6: ...om the device 2 Insert two AAA LR03 size batteries in the box with positive and negative terminals matching those indicated on the cuff 3 Slide the battery cover back on the device Insert the batterie...

Page 7: ...es may leak and cause a malfunction Use the specified batteries only The batteries provided with the device are for testing the monitor performance and may have a shorter life Using the Monitor 2 Fast...

Page 8: ...th We recommend you to rest twenty or thirty minutes before taking measurement Measure your blood pressure at about the same time every day 4 Measurement During measurement it is normal for the cuff t...

Page 9: ...to inflate It is normal for the cuff to feel very tight Note If you wish to stop inflation at any time press the START button again 3 The measurement starts automatically when pressurizing starts and...

Page 10: ...ect on your blood pressure This device bases its measurements on the heartbeat If you have a very weak or irregular heartbeat the device may have difficulty determining your blood pressure Should the...

Page 11: ...gular heartbeat occurs An irregular heartbeat is defined as a heartbeat that varies by 25 from the average of all heartbeats during the blood pressure measurement It is important that you be relaxed r...

Page 12: ...red in millimeters of mercury mmHg One s natural blood pressure is represented by the fundamental pressure which is measured first thing in the morning while one is still at rest and before eating Wha...

Page 13: ...regard to age have been established by the World Health Organization WHO as shown in the chart on the right Blood Pressure Variations An individual s blood pressure varies greatly on a daily and seas...

Page 14: ...u moved your arm or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortably and still Raise your hand so that the...

Page 15: ...ioning and accuracy Please contact either your authorized dealer or A D for maintenance Technical Data Type UB 511 Clinical test According to ANSI AAMI SP 10 1992 Measurement method Oscillometric meas...

Page 16: ......

Reviews: