background image

 

Page 9

 

Measurements 

Notes For Proper Measurement 

 

Sit down in a comfortable position. Place the arm to be used for the measurement on a table or other support so 
that the center of the cuff will be at the same height as your heart. 

 

Relax for about five or ten minutes before taking a measurement. If you are excited or depressed by emotional 
stress, the measurement will reflect this stress as a higher (or lower) than normal blood pressure reading and the 
pulse reading will usually be faster than normal. 

 

An individual's blood pressure varies constantly, depending on what they are doing and what they have eaten. 
What you drink can have a very strong and rapid effect on your blood pressure. 

 

This device bases its measurements on the heartbeat. If you have a very weak or irregular heartbeat, the device 
may have difficulty determining your blood pressure. 

 

Should the device detect a condition that is abnormal, it will stop the measurement and display an error symbol. 
See page 4 for the description of symbols. 

 

This blood pressure monitor is intended for use by adults only. Consult with your physician before using this 
device on a child. A child should not use this device unattended. 

Operation Mode 

1. Normal measurement with storing data 
  (Refer to page 8) 
  Press the START button. 
  Blood pressure is measured and data is stored within the device. 
  The device can store the last thirty sets of data. 
2. Recalling data 
  Press and hold the START button to recall the data. 
  Stored data are automatically displayed in order from the last data. 

Summary of Contents for UB-511

Page 1: ...Wrist Digital Blood Pressure Monitor Model UB 511 WM PD4000888A...

Page 2: ...easurement 7 Measurements 8 Normal Measurements 8 Notes For Proper Measurement 9 Operation Mode 9 What Is An Irregular Heartbeat 10 Pressure Bar Indicator 10 WHO Classification Indicator 11 About Bloo...

Page 3: ...fants Environment for use The device is for use indoors Precautions Precision components are used in the construction of this device Extremes in temperature humidity direct sunlight shock or dust shou...

Page 4: ...Page 3 Parts Identification...

Page 5: ...rtbeats or any excessive body movement during the measurement Previous measurements stored in MEMORY FullBattery The battery power indicator during measurement lowBattery The battery is low when it bl...

Page 6: ...om the device 2 Insert two AAA LR03 size batteries in the box with positive and negative terminals matching those indicated on the cuff 3 Slide the battery cover back on the device Insert the batterie...

Page 7: ...es may leak and cause a malfunction Use the specified batteries only The batteries provided with the device are for testing the monitor performance and may have a shorter life Using the Monitor 2 Fast...

Page 8: ...th We recommend you to rest twenty or thirty minutes before taking measurement Measure your blood pressure at about the same time every day 4 Measurement During measurement it is normal for the cuff t...

Page 9: ...to inflate It is normal for the cuff to feel very tight Note If you wish to stop inflation at any time press the START button again 3 The measurement starts automatically when pressurizing starts and...

Page 10: ...ect on your blood pressure This device bases its measurements on the heartbeat If you have a very weak or irregular heartbeat the device may have difficulty determining your blood pressure Should the...

Page 11: ...gular heartbeat occurs An irregular heartbeat is defined as a heartbeat that varies by 25 from the average of all heartbeats during the blood pressure measurement It is important that you be relaxed r...

Page 12: ...red in millimeters of mercury mmHg One s natural blood pressure is represented by the fundamental pressure which is measured first thing in the morning while one is still at rest and before eating Wha...

Page 13: ...regard to age have been established by the World Health Organization WHO as shown in the chart on the right Blood Pressure Variations An individual s blood pressure varies greatly on a daily and seas...

Page 14: ...u moved your arm or body during the measurement Make sure you remain very still and quiet during the measurement The cuff position is not correct Sit comfortably and still Raise your hand so that the...

Page 15: ...ioning and accuracy Please contact either your authorized dealer or A D for maintenance Technical Data Type UB 511 Clinical test According to ANSI AAMI SP 10 1992 Measurement method Oscillometric meas...

Page 16: ......

Reviews: